  1. ProWinder

    Sync motor test run

    Yes it is the brush type. Thank you for the info.
  2. ProWinder

    Sync motor test run

    Thanks for the link. I did not find that thread when I did a search.
  3. ProWinder

    Sync motor test run

    I want to test run a sync motor in the shop location. I have no name plate to get information from. I know the stator is 2300 VAC, 1200 rpm. Can I test run the motor as a squirrel cage motor on 600 VAC, leaving the rotor leads open? In doing this will the rotor work as an auto transformer and...
  4. ProWinder

    Internal motor connection question

    EngRepair, There are six leads out to be connected in parallel. (It is a 2 star connection) You could have one single lead but it would be a much larger conductor size. Span is the same all coils. The turns are all the same for each coil as well.
  5. ProWinder

    Internal motor connection question

    Thank you for the information. electricpete, I would like to know what school you're attending to learn all this information. I have only got on the job learning (12 years) with zero schooling on theory. I am also apart of a joint apprenticeship committee with my employer. It would be great to...
  6. ProWinder

    Electric Motor Bearing Heaters

    Water in the windings due to condensation can cause the windings to be grounded. Then upon start up it will break down and let the smoke out.(LOL)
  7. ProWinder

    Internal motor connection question

    Can any one please explain to me why this motor is connected in this manner. Thank you
  8. ProWinder

    Wound rotor motor.

    Thanks, that is what I thought it would be. Just wanted to be sure.
  9. ProWinder

    Wound rotor motor.

    At what rpm does a wound rotor motor have full nameplate horse power? Will it have the same horse power regardless of the rpm it turns at?
  10. ProWinder

    DC Motor Trouble

    Well we found out the problem. The internal connection of one inter pole was pinched against the series winding leads. This gave us bucking fields. Once we isolated the two the motor ran just fine.
  11. ProWinder

    DC Motor Trouble

    The drum switch is part of out test panel. The test panel was built 40 years ago. I think I will have to try running the motor from a welder to avoid using the test panel. I don't think the test panel is the problem, or the drum switch for that matter. Thanks for the help I will try a few of...
  12. ProWinder

    DC Motor Trouble

    when s1 and s2 are switched the motor changes direction. however it will not change direction when we switch the drum switch to reverse the motor.
  13. ProWinder

    DC Motor Trouble

    Waross, if this was the case should the motor still turn ccw or would it just not run at all? With the motor apart I did trace the leads and did not see any thing stand out to be out of place.
  14. ProWinder

    DC Motor Trouble

    The wiring diagram for the drum switch I don't have. The connection does match the diagram you posted. I have run other series motors without any troubles of reversing direction with the test panel we are using. This motor is should be easy to test run but doesn't make any sense.
  15. ProWinder

    DC Motor Trouble

    This is a series motor. I did change just the a1 and a2 leads, no change in direction. Change s1 and s2 and the motor will turn the other way. This is done and the drum switch that we are using is switched the same way with the motor leads in different locations. The strange part of this is...
  16. ProWinder

    DC Motor Trouble

    The motor will not (sorry) turn in the cw direction. We are using a drum controller to test run the motor. With this we can change motor direction without moving the motor leads. We did try out a different motor to see if the test panel had a fault. The other motor ran just fine. All of...
  17. ProWinder

    DC Motor Trouble

    We are working on a Westinghouse motor. Frame 620-MCA Volts 230 DC rise 75 Deg C Series Wound HP 275 RPM 370 Amps 975 Hrs 1 HP 360 RPM 340 Amps 1280 Hrs 5 Looking at the com side of the motor it will run ccw and...
  18. ProWinder

    Coil grouping Constant Torque Motor

    Thanks for the info Guys.
  19. ProWinder

    Coil grouping Constant Torque Motor

    I am rewinding a constant torque motor. The motor is 4 pole and 8 pole. 54 slots. The groups are odd number. 6 groups of 4 and 6 groups of 5. The coils can be put in the stator in order of 454 545 454 545 or 454 454 545 545. Why is the second order the correct one. The groups need to be...