  1. CarlB

    Frost heave in saturated gravel below foundation

    If you think the groundwater can be controlled sufficiently to perform earthwork to that depth, why not instead just place the pier below the frost level and forego the subgrade replacement with gravel? The gravel replacement idea should provide adequate foundation support, as the chance of...
  2. CarlB

    Grading Tolerances

    You mentioned 'tolerances', what are they, what is required by the specifications? For a finished surface of earth (vs pavement), a typical tolerance (allowed deviation from design grade) is something on the order of +/- 0.05 feet, or about 1/2 inch. The tolerance would be independent of slope...
  3. CarlB

    Project Geotechnical Report

    That soil type (silty sand), very low blow counts, below the water table, present very high chance of liquefication during a seismic event, leading to settlement, sand boils, etc. Unless site is in a very low seismic region.
  4. CarlB

    Grenoble method for pile uplift verifications

    The following paper appears to have a worked example using the Grenoble method...
  5. CarlB

    AutoCAD: How do I stop OSnap defaults from overriding @(relative x, y) coordinates?

    Not all system variables can be set through user accessed settings, but this one can be apparently (I read online, didn’t verify): Tools/Options/User Preferences/Prioroty for Coordinate Data Entry ... select "Keyboard Entry" vs "Running Object Snap".
  6. CarlB

    AutoCAD: How do I stop OSnap defaults from overriding @(relative x, y) coordinates?

    Set OSNAPCOORD to 1 or 2 to prevent osnaps from controlling during coordinate entries https://help.autodesk.com/view/ACD/2025/ENU/?guid=GUID-94994960-5E62-4044-BEF7-9CF91667F641
  7. CarlB

    Floor drain flow rates

    I would think the PC design/sizing is more a function of the maximum expected inflow rate, rather than daily flow rate. The PC size is as necessary to limit number of pump starts per hour. So maybe you should be asking the ME, and possibly the bakery, what is the maximum expected flowrate &...
  8. CarlB

    Foundation Design Consultations - Need Guidance

    Regarding #2: I'm guessing by "shear", this is lateral load from the structure that will transfer to the foundation. But depending on how the load is transferred, some may be resisted by grade beams (setting on the earth) and grade slabs. It some cases it may be reasonable to assume that those...
  9. CarlB

    Interior Face Frost Protection Depth for Unheated Space

    Your scheme leaves some cold bridges from the inside cold temperatures, to the footing. The below additional insulation could address that. Though the slab itself could experience frost effects.
  10. CarlB

    Length of Need for guardrail next to creek

    A waterbody does not fit the "length of need" scenario shown by the figure, as it is not a hard/fixed object. The "back" is the far point of the object from the roadway, that is to be shielded with a guardrail. In the case of a waterbody or steep slope, extend guardrail as needed to keep errant...
  11. CarlB

    Testing Device for Foundation Depth???

    You should contact a geophysical services firm, there are a lot of methods for detecting/mapping subsurface conditions. One example: https://geophysicalservices.com/locate-deep-facilities-eri-em-masw-pulseekko-ultra-gpr-magnetometers-buried-cables-voids-pipes/
  12. CarlB

    Any transportation gurus here? Driveway Aprons purpose.

    An apron also reduces amount of gravel that gets carried onto the road, which can be a safety hazard and projectile for windshield damage.
  13. CarlB

    Calculating capacity in ditch section with uphill slope

    Backwater analysis. Assume a flowrate. Starting at downstream end, should be some controlling water level, or free-flow. Break ditch into sections of similar cross-section. For each, calculate HGL to achieve assumed Q, such as with Mannings equation. Carry elevations upstream. End result is...
  14. CarlB

    Detached Garage Foundation

    As mentioned, ASCE 32 provides methods for insulating below an unheated building to prevent frost penetration. There are no allowances/reductions for interior footings. Where is this energy coming from that may lessen the frost depth? The air temperature inside and out should be essentially the...
  15. CarlB

    soil mechanics

    I believe the pore pressure being referred to is actually "excess" pore pressure, which is the amount above pressure due to gravity. So by zero pore pressure they actually mean hydrostatic.
  16. CarlB

    Uncased Buried HDPE Water Pipeline

    PPI handbook, Chapter 6, buried pipe design should have what you need https://www.plasticpipe.org/MunicipalIndustrial/Shared_Content/Shop/PE-Handbook.aspx
  17. CarlB

    Can anyone help me in identifying t

    The method is discussed in this thread- https://www.eng-tips.com/viewthread.cfm?qid=513013
  18. CarlB

    Crane Turning path

    Turning radius (inside and outside) in specs at https://www.fleetfile.com/crane/specifications/type_id=650
  19. CarlB

    Origin of Drilled Post Foundation Equations in IBC

    Thanks for the update. I did some research as well, may add on to what you find. Regarding the question of d/3- A maximum of d=12 feet is a limit just for determining the lateral soil pressure, S1. That is, for cases where d is greater than 12 feet, use d=12' for determining S1. Which mean the...
  20. CarlB

    soil heat transfer/temperature change air drain

    The attached figure may be of assistance. The approach is designed for temperature change of water, but seems the equations should be valid for air flow, just use properties for air and correct units...