Online Running Testing mean the pump will be put on service while the Steam Turbine is running at Full Load.
I am sorry if it make a confuse to everybody, what I mean with Jacking Oil Pump is pump that supply oil for lifting up the turbine rotor. Usually use in the first start up or during...
Dear All,
We operate steam turbine 55MW in base load condition. Rotor weight is around 32000 kg. The jacking oil pump discharge is 130 psig and the line has PRV at 150 psig.
There is a question from our operation team, is it allowed to conduct online running testing of jacking oil pump?