  1. Diabolico

    Cooling capacity using water vs. 60/40 EGW

    Does anybody know how to quantify the performance difference when using 60/40 egw instead of water in a chiller evaporator that uses R134a refrigerant?
  2. Diabolico

    Portable chiller performance

    I understand that portable air cooled chillers loose cooling capacity at higher ambient temperatures. My question is, how does high humidity affect the cooling capacity? is humid hot air worst than dry hot air? Thanks
  3. Diabolico

    voltage and frequency converters/transformers

    SReid, Who do you work for if I may ask? I work in the Boston area for a chiller manufacturer.
  4. Diabolico

    voltage and frequency converters/transformers

    sreid, who do you buy your chillers from?
  5. Diabolico

    voltage and frequency converters/transformers

    Does anybody know of a product out there that converts not only voltage but frequency? I work for a chiller manufacturer company and I constantly have customers asking if theycan convert our 230VAC 60 Hz units to 115 VAC 50 HZ. I know there are voltage converters and frquency conveters. Is ther...
  6. Diabolico

    Condensation on chiller supply/return hoses

    I am looking for information on how to calculate the cooling capacity loss by a recirculating chiller due to operation in a humid environment. The chiller coolant, typically supplied via a rubber hose to a process to be cooled, condenses the water vapor in the air. Lets say the collant...
  7. Diabolico

    Equivalent water temperature in a parallel and series piping systems

    The 1gpm stream would heat up to 52.6 C, while the 3gpm stream will heat up to 46.3 C. What is the resulting temeperature when these two streams converge again to 4gpm??
  8. Diabolico

    Equivalent water temperature in a parallel and series piping systems

    My question is: How do you find the equivalent water temperature in a series or parallel system? Ex: you have 4 gpm of water @ 45 C splitting into two legs of which one 1gpm leg absorbs 2 kW of heat and the other 3 gpm leg absorb 1 kW. Whatis the equivalent temperature coming out of these two...
  9. Diabolico

    Heat Exchanger Calc's

    You want to use the specific heat equation: Q = m x Cp x DeltaT Q = Heat load (BTU/hr) m = mass flow rate (lbs/hr) Cp = specific heat of coolant DeltaT = temperature differential between inlet and outlet From this formula: Tin = Tout + Q/mCp Tin = 120 + 150000/(10 gpm x 66.4...
  10. Diabolico

    heat added to fluid by pump

    How do I calculate the heat added by a pump (turbine, PD, centrifugal)to the coolant on my chiller?
  11. Diabolico

    pipe material compatibility with distilled water

    Is distilled water as corrosive to stainlees steel (316L) as DI water? is copper or aluminum compatible with distilled water?