  1. ben3929

    Fall restraint anchorage point capacity.

    For fall arrest system anchor point must be withstand min. 5000 lb force/person. However, what is OSHA recommended fall restraint anchorage point minimum capacity? Is it the same as the fall arrest anchor point? I have read min. 1000 lb/person for fall restraint anchor point in some technical...
  2. ben3929

    Exhaust Duct

    What are the requirements to exhaust low-heat industrial appliances? Industrial oven rated 500 F and needing exhaust duct to flue hot gases out. I was informed to use class A double wall insulated duct and most of the duct manufacturers are not familiar with this classification. What is the...
  3. ben3929

    Utility Support

    I am working on a project to install utility support frame. The utility load rate estimated 10 psf. The roof assembly is consists of cold formed steel joist, hard ceiling and metal deck roof top as shown in the attached picture. we are planning to install the metal deck prior to the hard...
  4. ben3929

    Rupture Disk specification

    I need help to specify burst pressure and burst temperature of rupture disk. Operating condition of system: nitrogen compressed gas thru dia. 1" tube vessel working pressure 4500 psi. compressed gas supply pressure 2500 psi @ ambient temperature, 400 cfm. outside temperature -40F to 140F...
  5. ben3929

    Pipe size for nitrogen gas

    Thanks for your response, both. I am sure if I understand the math correctly, if possible would you show how you come up with 1.5" pipe diameter.
  6. ben3929

    Pipe size for nitrogen gas

    Assume the inlet pressure from tank is constant. There is another pressure regulator at the tank station.
  7. ben3929

    Pipe size for nitrogen gas

    Need help to calculate pipe size for nitrogen gas (from tank to pressure regulator). known values are inlet pressure from tank 1500 psig, length of pipe from tank to pressure regulator 300 ft, flow rate 600 SCFM (17000 slpm), assume 5% pressure drop for fittings, pipe end will be connected to...
  8. ben3929

    recommended gasket type

    what type of gasket is recommended to use for water pipe line? water pressure 300 PSI. spiral wound metallic gasket vs EPDM rubber gasket?
  9. ben3929

    How to read frequency from pump curve

    Four pumps in parallel with VFD control on each pump will be used for my project. total head 432 ft, required total flow 130 gpm and there is a bypass circuit to the system. the manufacturer recommended min. fluid flow of 7 gpm for each single pump. the min. demand flow rate is 10 gpm. i have...
  10. ben3929

    Pump system curve for branching system

    If possible, I need an example or excel spreadsheet calculator on how to calculate or generate pump system curve for branching system with multiple destination (with various pipe size) and single source of fluid (single pump). I believe this is different than a system consisting of a single...
  11. ben3929

    total static head

    Is the total static head in the attached diagram (B+D)-A or (D+B+C+B)-A.https://files.engineering.com/getfile.aspx?folder=1c2be0eb-53b1-462e-a91b-98432a616df1&file=head.pdf
  12. ben3929

    Weld

    What is the best practice of fillet welding for steel undergo vibration? Someone informed me that it is preferable the weld perpendicular to the vibration plane? Is this true. It is a 12" long 1/4" fillet weld size.
  13. ben3929

    Compressed air system

    I need help to design/size compressed air system that includes compressor, air dryer and receiver tank. Given data are the air demand, air pressure and running time to start an engine. It would be great, if you direct me an example on how to size air compressor, air dryer, and receiver tank.
  14. ben3929

    Fill pit with concrete

    I am working on a project to fill several pits inside an aircraft hangar with concrete. Pits are 5ft by 5ft and 5ft deep in size. My questions are: do I need re-bar, what is the best solution to avoid shrinkage. Any feedback would be appreciated. previously pits were used as media reclamation...
  15. ben3929

    Expansion Joint

    The allowance provided on the roof is 2" and less than 1" on the floor. existing building size is 1/2 mile by 1/2 mile. the slab supports heavy equipment and vehicles.
  16. ben3929

    Expansion Joint

    A two story office building will be constructed inside existing industrial building. The existing building has movement joints (expansion joints)on concrete floor. The new two story building (135'X45') will be built crossed over existing concrete slab expansion joints. New building will not be...
  17. ben3929

    Concrete paving over asphalt

    Should I place rebar or welded wire mesh for the concrete pavement.
  18. ben3929

    Calculating CFM from PSI

    Perhaps let me try clarifying my question the following way."X" amount of pressure delivered to your car tire through "d" size pin hole tube. With known time "t" how much air volume fill the tire.
  19. ben3929

    Calculating CFM from PSI

    How do I calculate compressed air flow rate in CFM using diameter of pipe, density of air, temperature of air, and pressure of air at drop station? I used the equation Q= (area^2)* sqrt((2*pressure/density)) but my result is not matching with the graph shown in the link below...
  20. ben3929

    Concrete paving over asphalt

    I am working on a project to install industrial shop in an existing storage area. Existing floor in the storage area is 18 inch thick asphalt pavement and the shop needs a concrete pavement. golf carts and forklifts will be operated over the new concrete pavement. I was told to remove 6" of the...