Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. senthil83

    Calculating the allowable stress in creep range of 200000 hrs operation

    Dear all, we had a requirement from customer to design the pressure vessels for 200000 hrs of operating life. we have the materials using in the creep range, so how to calculate the allowable stress for ASME materials at 200000 hrs operation. ASME Sec II D has 100 Favg% rupture stress at...
  2. senthil83

    Cone junction reinforcement as per ASME Sec VIII Div 1

    hi, we are analyzing a vertical vessel of diameter 8400mm with height 26000mm, supported by skirt and cone section at bottom, while checking the junction of cone to cylinder at skirt location, we are doing reinforcement calculation as per ASME Sec VIII div 1 appendix 1-8 for external pressure...
  3. senthil83

    spacing of process columns for wind effect

    we are designing closely spaced process columns for wind loading - size of columns are Dia 3000mm x 30m height, spaced at a distance of 5m between two cylindrical columns. Is there any special consideration needs to be done for the close spacing under wind loading conditions? Regards...
  4. senthil83

    API 650 Chapter 5.12, UPLIFT Loads

    As per API 650 clause 5.12 tank anchorage, table 5-21a shows uplift load calculation formula including seismic case as (4xMrw/D)-W2(1-0.4Av). In this W2 is given as dead weight of the shell and roof. since for seismic moment (Mrw) calculation we are including the content weight(liquid weight)...
  5. senthil83

    dual system specification

    thanks for the reply
  6. senthil83

    dual system specification

    i am working on a project where i am using braced frames on x- direction and ordinary moment frame on y-direction. whether this structure needs to be designed as dual system or analysis with seismic + x with R value of braced frame and seismic +Y with R-value of OMF is enough for the seismic...
  7. senthil83

    colombian seismic code nsr-10

    dear all, i am using colombian seismic code nsr-10 for one of my project. i have doubt, as per code i have calculated seismic base shear as Vs = Sa g M How to use the R-value in the seismic calculation. there is no formula given in code on using it in seismic base shear calculation. please...
  8. senthil83

    anchor bolt bottom plate welding

    we are using anchors bolts with bottom nut and washer. refer attachment. in order reduce the anchor rod bottom side threading and nut. we propose to use only bottom plate washer welded to anchor rod without nut. IS it OK in terms of pullout strength requirement? regards...
  9. senthil83

    shear key pocket

    what will be the edge distance from the shear key pocket size to anchor bolts center.
  10. senthil83

    pile and pile cap curing time for removal and loading

    i have been working on a pile foundations, I need to know what will be minimum time required for curing of concrete before commencement of following works after piling, 1.pile breaking to cut off level. 2. pile intergrity test 3. pile cap & pedastal concreting. 4. form work removal. 5. pile...
  11. senthil83

    routine pile load testing as per IS2911

    dears, we are designing the pile foundation, where there are requirement for pile testing for routine pile test and initial test pile. initial test pile to be done for 2.5 times the safe load and routine pile test to be done for 1.5 times the safe load i have a doubt whether the reinforcement...
  12. senthil83

    base plate with large moment

    i am designing a column base plate with large moment as per aisc design guide -1, P = 2000 kn Mu = 5000 kn-m due to higher moment, i am getting very large base plate dimension to satisfy inequality eqn. how to reduce it? regards,
  13. senthil83

    x-bracing intersection connection

    thanks for your replies, this x-bracing is already in site, we want use with minimum repair, what would be the good solution? introducing the gusset at center, but the there is no enough length
  14. senthil83

    x-bracing intersection connection

    hi we have been using x bracing in our support structure, refer the attached sketch where the support structure was designed as SCBF(special concentric braced frames) since there is no length at x-bracing intersection for making gusset conn, we have made direct pipe to pipe welding at...
  15. senthil83

    Sox and Nox emission performance test

    dears, what is the American standard used for the SOx and Nox Emission performance test. thanks senthil
  16. senthil83

    asme code stamp requirement as per asme sec viii div-1

    dears, we are designing a condensate storage tank with following properties, is this tank has to be code stamped as per asme sec viii div-1 Operating pressure - 2 bar temperature - 200 deg.c Capacity - 10 m3 thanks
  17. senthil83

    h/tw limit for the star type steel column

    hi we are using the star type columns, refer attached sketch for calculating the h/tw limit for section classification as per aisc, can we take half of column depth as h (H/2) for the calculation. Since this is symmetric t-sections about center. regards, senthil...
  18. senthil83

    equivalent american standard for en14015

    Dears, what is the equivalent American code for en14015 - Specification for the design and manufacture of site built, vertical, cylindrical, flat-bottomed, above ground, welded, steel tanks for the storage of liquids at ambient temperature and above?// thanks senthil
  19. senthil83

    ASME STS -1 QUESTION

    yes thats correct, thanks