    12 ft dia meter condenser min wall calculation

    Thanks everyone for the useful answers. Yes, it is a steam surface condenser. It is 3/4 inch thick and under 14.1 psi pressure. I will check out the codes. As mentioned, we got it in 1968 from a company that went out of business 20 years back. And, I could not find any minimum wall requiremnt...
  2. sshh

    12 ft dia meter condenser min wall calculation

    Thanks ... it is vacuum pressure....condensing water.... it is a 1968 condenser installed at the power plant....
  3. sshh

    12 ft dia meter condenser min wall calculation

    I am trying to find the min wall requirement for a 12 ft dia meter condenser. TEMA does not apply since the diameter is greater than 100 inches and ASME section VIII 16 doest not apply to heat exchangers. How can i find the min wall required? Thanks
  4. sshh

    asme sa 240 304 L mechanical property

    Thanks metengr. Found it.
  5. sshh

    asme sa 240 304 L mechanical property

    Hi, Which section of asme code specifies the minimum elongation of 40 % for sa 240 304 L? Thanks http://files.engineering.com/getfile.aspx?folder=8e28773f-2fcc-4adf-a3af-3a415c49c504&file=properties.docx