  1. gazibu

    NYC Building Code 2008 requirements for adding floors to exisitng older buildings

    I know that and I have the code.The question is if any ones knows where and if at all this issue is discussed in the code in chapter 16 (or anywhere else).
  2. gazibu

    NYC Building Code 2008 requirements for adding floors to exisitng older buildings

    I was wondering if any one knows the requirement of design for existing buildings that would be adding new floors.My understanding is the IBC code requires buildings to be designed based on the most recent code if the added load on the existing building exceeds 10%. What does NYC building code...
  3. gazibu

    wind load design based on NYC building code 2008

    Can some one tell me when it comes to wind pressure acting on cladding and components,(walls) do you add the windward and leeward pressures or each acts separately? Thanks
  4. gazibu

    Has anyone taken the ICC welding (S2) exam required for special inspections?

    Has anyone taken the ICC Welding (S2) exam? If so any hints as to what study material is best to prep for the test, besides the standard welding codes? Thanks
  5. gazibu

    NYC -DOB Special inspection requirement for Structural welding & bolts

    Does any one know whether the NYC DOB requirement for special inspections (TR-1) requires PE license & ICC certification for welding and bolting is mandatory or still pending further clarification and new rules? PE's with over 10-15 years of relevant experience also require the ICC certification?
  6. gazibu

    Special Inspections, TR-1, NYC

    Can any one explain the purpose of the last inspection item on the form, referred to as "final, Directive 14". I have a case where I have been asked to provide special inspection for High strength bolt, welding and structural stability,for a small renovation job, however I have been additionally...
  7. gazibu

    Extent of underpinning to be shown on drawing

    Yes. This is an addition for an existing 4 story building in NYC with adjacent similar 4-6 story buildings on either side.
  8. gazibu

    Extent of underpinning to be shown on drawing

    can anyone tell me the extent of underpinning details that is required to be shown on the structural contract drawings in NYC for getting permits? Do the structural drawings need to show all the excavation bracing details under the existing underpinned elements, or can the specifics of the means...
  9. gazibu

    laminated glass vertical panels

    When you say load duration assuming the load in question is wind ,how does the duration come in to play?
  10. gazibu

    laminated glass vertical panels

    Are you implying that the 6000 psi/ 6 ksi value I have been considering is way too conservative versus your 13.5ksi? also is this value also applicable to laminated glass?
  11. gazibu

    laminated glass vertical panels

    I am somewhat familiar with ASTM E1300. Do you know where it can be downloaded or viewed without having to purchase it? Thanks
  12. gazibu

    laminated glass vertical panels

    I have a laminated glass panel wall that is spanning vertically 6 ft and fixed at the base. Typically I have seen modulus of rupture values of 24000 psi for glass panels (tempered/laminated).Also typically a factor of safety of 4 is used to obtain the allowable bending stress = 6000 psi.Does any...
  13. gazibu

    stress reduction when designing handrail and railing

    I Know the nyc (new york city ) code specifies the 200 lb, concentrated and 50 lb uniform load, but can the determined stresses be reduced by 1/3 , similarly to wind and seismic forces? that is my question.
  14. gazibu

    stress reduction when designing handrail and railing

    As it is known commonly when designing handrails as per the code one designs for a concentrated force of 200 lb, or uniform load of 50 lb/ ft.My question is does the nyc code allow for 1/3 stress reduction in this case? can the 200 lb load be considered temporary, to allow for the stress reduction?
  15. gazibu

    question about wind load analysis of a open top screened structure

    Thanks for your detailed response. I checked the wind pressure using the gcpi= + -0.55 (partially enclosed structure), which gives the highest wind pressure.Additionally I suppose to be conservative I can add the positive and negative internal pressures. If the existing members work for this...
  16. gazibu

    question about wind load analysis of a open top screened structure

    I understand that we cannot take any reductions, but it seems to me it is probably more realistic to analyze this as a other-structure system (as outlined in Fig. 6-20 ASCE-02 for solid free standing walls and signs).
  17. gazibu

    question about wind load analysis of a open top screened structure

    I was wondering if some one can provide guidance form the following wind analysis condition: a metal screen that is supported by vertical and horizontal steel tubes is supported on top of a 18 story bldg.the screen has 3 sides and the fourth side is the side of the existing bldg.The screen is...
  18. gazibu

    Friction-Grip bolted connections for structural glass

    Thanks for the feedback guys, as suggested I am probably better off contacting the manufacturer, as this is not our typicall structural problem.
  19. gazibu

    Friction-Grip bolted connections for structural glass

    Take a look at the enclosed info, specifically the last article as it relates to the use of friction-grip bolts for this purpose.The info on the first page relates to the design of high strength friction-grip bolts, but I am not sure if it applies to structural...