Thanks for reply @ Bartosz
My connector element is on wire(wire-1-set-1) which is connected to reference point RP-1100 and RP-22. You can check connector assignment.
Regards
Vikash
Nodal force and displacement containing connector element remain zero with increase in load. Can anyone expalin.
https://www.dropbox.com/s/it3rkmfd31bk0k3/25mmMS.cae
https://www.dropbox.com/s/buz5ar62z6faf26/25mmMS.jnl
Thanks
I am getting displacement and force both zero. I am attaching .cae file please have a look where i am making mistakes.
https://www.dropbox.com/s/it3rkmfd31bk0k3/25mmMS.cae
https://www.dropbox.com/s/buz5ar62z6faf26/25mmMS.jnl
Thanks
1 nodes have inactive dof on which boundary conditions are specified. The nodes have been identified in node set ErrNodeBCInactiveDof. Please suggest. Model is attached
1 nodes have inactive dof on which boundary conditions are specified. The nodes have been identified in node set ErrNodeBCInactiveDof.
I have attached the model please have a look and give some suggestion. Thanks