Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. mabel12

    High Temperature Excursion on a Reactor Tube

    Thanks for the responses folks. Just to add. Yes, this is registered equipment, but it's a tubular reactor, so it's actually considered a really long segment of pipe (not a vessel). Inspection requirements are a little different for pipe versus vessel around here. I can get away with X-ray...
  2. mabel12

    High Temperature Excursion on a Reactor Tube

    Thanks for the feedback! Design pressure for the reactor is 45ksi, all relief devices are set to this, and the reactor never got above that pressure. I was just concerned about the temperature effects. I am very limited regarding inspection and NDE options: no internal access (even for remote...
  3. mabel12

    High Temperature Excursion on a Reactor Tube

    I have a reactor tube that (during an excursion) saw pressures of about 43.5ksi (300MPa) and reached 2372F (1300C) for approximately 45 seconds (very worst case scenario). The reactor tube is AISI4340 material and approximately 2" thick (2" ID). Reaction was instantly killed after that excursion...