  1. SCEngr1

    Wood Jack Stud check

    I have seen simple and more complex calculations for the checking the stress from roof framing to jack studs. My question is: Can you use simply the Fc (compression parallel to the grain) allowable stress and compare to the fc = P/A? Or is it necessary to compute Kce, Cp, etc. for the more...
  2. SCEngr1

    Concrete on Asphalt?

    Thanks for all of the posts and feedback. Drumchaser, this is an existing ASPHALT parking lot. The larger pothole areas indicate a very thin (1.5" - 2") asphalt directly on clay (no gravel or crusher run sub-base). So, I guess milling would not be an option, is that correct? Would recycling...
  3. SCEngr1

    Concrete on Asphalt?

    If an existing parking lot for a private ambulance service has a lot of chuck holes and broken pavement areas, is it feasible to clean the loose debris and then cover the entire lot with concrete? The parking lot has approximately 50% of the total area with broken pavement that needs either...
  4. SCEngr1

    Free contour maps

    Thanks for the links. I can't seem to find any free download. It wants me to order a map for a fee. I guess that is the only way to get a topo map on-line - to pay for it? ("You're only as old as you feel." - Satchel Paige)
  5. SCEngr1

    Free contour maps

    I need to get a rough estimate of the off-site flow onto a project site. Are there free CONTOUR MAPS available on-line? ("You're only as old as you want to feel." - Satchel Paige)
  6. SCEngr1

    Asphalt resurfacing

    Great information! Thanks for the feedback!! ("You're only as old as you want to feel." - Satchel Paige)
  7. SCEngr1

    Asphalt resurfacing

    Would you have to run some non-destructive tests on the parking lot to determine the condition of the existing pavement? What if the client's budget is real tight? Are there some reasonable assumptions that could be made to develop a recommendation for repairs and overlay? ("You're only...
  8. SCEngr1

    Asphalt resurfacing

    Is this on the wrong forum? ("You're only as old as you want to feel." - Satchel Paige)
  9. SCEngr1

    Asphalt resurfacing

    What about the surface repairs and new topping layer thickness? ("You're only as old as you want to feel." - Satchel Paige)
  10. SCEngr1

    Asphalt resurfacing

    I have a project with an existing asphaltic concrete parking lot. The parking lot has several cracks in it as well as a recently cut trench for a water line installation. The trench has some soil fill material that was placed in it to cover it up, but it has not been covered with asphalt or...
  11. SCEngr1

    Pond volume vs. Peak discharge

    How do you model a vortex valve in HydroCAD? Are they very expensive? Are they very common? ("You're only as old as you want to feel." - Satchel Paige)
  12. SCEngr1

    Pond volume vs. Peak discharge

    Thanks for the help! I will try those various options. ("You're only as old as you want to feel." - Satchel Paige)
  13. SCEngr1

    Pond volume vs. Peak discharge

    The target outflow rates are: For 2-year: 11.46 cfs For 25-year: 29.40 cfs So, since the 2-year event is discharging through the emergency spillway, I need more pond volume, correct? "You're only as old as you want to feel."
  14. SCEngr1

    Pond volume vs. Peak discharge

    Here is the attached file of the HydroCAD model. "You're only as old as you want to feel."http://files.engineering.com/getfile.aspx?folder=6d8a236d-24be-45ed-8f32-fe60577d244f&file=Windsor.hcp
  15. SCEngr1

    Pond volume vs. Peak discharge

    I used the HydroCAD sizing feature for ponds to get an initial estimate of the pond volume required (using the pre-developed 50-year runoff flowrate). Then I set up my model to reflect the post-developed flow (Subcatchment) routed to the pond and then routed to a Reach (the receiving basin /...
  16. SCEngr1

    Stormwater Modeling Software Opinions

    What about HYDROCAD VS. HYDRAFLOW??? I really like HydroCAD's modeling (more user friendly) as well as the look of the print outs. Also, I just don't understand why the pond size required by the two programs would be off by a factor of two!
  17. SCEngr1

    Stormwater Modeling Software Opinions

    I had been using HydroCAD previously, but now I'm being asked with my new firm to recommend whether we stay w/ Hydraflow - that they had been using - or switch to HydroCAD. Hydraflow is now part of the Civil 3D software that we are using. However, there is virtually no tech. support. Also...
  18. SCEngr1

    Fire Hazard Classification?

    The IBC 2003 code is in effect by the local government. MSDS sheets state the following: - Paint, Flammable Liquids UN 1263 - Flash Point (closed cap): -4 to 160 F - Approx. flammable limits: 0.8% - 16% - V.O.C. (lbs per gal.): 0.0 - 7.5 - when heated above the flash point, emits flammable...
  19. SCEngr1

    Fire Hazard Classification?

    This is a paint storage room with the ability to mix some different colors in a closed mixing device. They sell the custom colored paint to automotive paint shops for their use. The retail space is part of leased space in an existing strip mall. The existing retail space and strip mall does...
  20. SCEngr1

    Fire Hazard Classification?

    For a 10'x12' automotive paint mixing room (closed cap system), can we provide the one-hour fire barrier between this room and the retail space WITHOUT installing an automatic sprinkler system? Also, how do you determine the "Fire Hazard Classification"?