Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. DavidOC

    AS4343 Hazard Level for Vacuum Tank

    If depressurised during transport it is a static vessel. See AS 1210 3.26.2.
  2. DavidOC

    AS4343 Hazard Level for Vacuum Tank

    There used to be exemptions in the QLD Workplace Health and Safety Regs for some vacuum vessels, however, I believe current legislation only looks at hazard level. See Schedule 4 in this link for the old requirements. http://www.legislation.qld.gov.au/LEGISLTN/REPEALED/W/WorkplHSR89_01_.pdf
  3. DavidOC

    Maximum socket weld gap?

    Pennpiper, From ASME 1: PW-41.5.2 The depth of insertion of a pipe or tube into a socket shall be at least 1/4 in. (6 mm). There shall be at least 1/16 in. (1.5 mm) clearance between the end of the pipe or tube and the internal shoulder of the socket, before welding.
  4. DavidOC

    Maximum socket weld gap?

    If there is an internal shoulder, then yes, the minimum socket depth would neeed to be 5/16" to meet the PW-41.5.2 requirements.
  5. DavidOC

    Maximum socket weld gap?

    ASME 1 PW-41.5.2. Depth of insertion shall be at least 6 mm.
  6. DavidOC

    AS 3920.1 definition of plant

    kasimmehdi Form 100 is the application form for design registration. If you are registering pressure equipment design, an independent design verification to AS 3920.1 is required. AS 3920.1 only applies to pressure equipment - not to other types of plant that need design registration.
  7. DavidOC

    AS 3920.1 definition of plant

    http://www.slp.wa.gov.au/legislation/agency.nsf/docep_main_mrtitle_650_homepage.html
  8. DavidOC

    AS 3920.1 definition of plant

    The definition of plant will vary slightly from state to state. In Queensland plant includes "machinery, equipment, appliance, pressure vessel, implement and tool". You will need to check the actual definition in the WA legislation.
  9. DavidOC

    Minimal Weld Spacing in Piping

    From the original post, the gap is greater than 3/4" and pup piece is less than 10 mm. This still leaves a root gap in excess of 4.5 mm for each of the welds. You may want to check this complies with the WPS (see 328.4.3 (d)). If you want some assurance on the quality of the weld, you could...
  10. DavidOC

    Double Interpolation of Tabular Data

    Interpolation in excel is a pain. It can be done using various lookup functions. The only way I know how to do it is to use index and match functions to find the data around the point you are interested in and then do the interpolation calculation. For steam tables you can download a free...
  11. DavidOC

    Flow resistance in piping bends

    KB in A-29 includes resistance due to the length of the bend. See discussion on P 2-13. Also note the difference between Kb and KB.
Back
Top