  1. GGMurphy

    690V Portable Gensets UK

    Does anyone know of a supplier local to the UK that provide portable gen sets capable of 690V?
  2. GGMurphy

    Radioactive Level Measurement

    The vessel is already constructed, we are currently using a hybred device which is a Berthold Nucleonic Density measurement device connected to a Enraf servo motor. This has made for an interace profiler, we no longer require the profile option and the device needs scrapping due to mechanical...
  3. GGMurphy

    Radioactive Level Measurement

    Its pure HF Acid, the temperature range of the vessel is -15degC to 120degC and the max pressure is 18.5barg. The wall material is killed carbon steel (21mm thick. The range is 9.1m. No set accuracy, but as good as possible.
  4. GGMurphy

    Radioactive Level Measurement

    I want to measure the continous level of HF Acid in a 10m high vessel. I have to use a radioactive level measurement device as they are the only type to be completley non-contact. Can anyone recommend a Radioactive level device? So far I have only came across the models from Ohmart-Vega, E+H...
  5. GGMurphy

    E&H Level Radar Positoned in the Centre of Vessel

    I am currently looking at installing an Endress + Hauser Micropilot M FMR231 Level radar on a 13m HF column. Unfortunately the only nozzle available to connect the radar to is directly in the centre of the vessel, this is not ideal for radars as the walls give off false echoes that reduce the...
  6. GGMurphy

    HFA Settler Interface Level Measurement

    Are there not any serious safety implications on using the Fisher device with it being in contact with the process? Is there a risk involved when calibrating it also? Our current device is a Berthold radioactive density measurement device that like yours send the source and detector up and down...
  7. GGMurphy

    HFA Settler Interface Level Measurement

    Which model are you using? Vega is the UK name of Ohmart so I have access to their models. Is this for an interface level application?
  8. GGMurphy

    HFA Settler Interface Level Measurement

    I want to measure the interface levels in a Hydrofluoric acid settler. Due to the nature of HFA a non-contact measurement device is strongly preffered. So far the only non-contact solution that appears to be capable of measuring the various interface levels is a Vega nucleonic density...
  9. GGMurphy

    HFA Settler Interface Level Measurement

    I want to measure the interface levels in a Hydrofluoric acid settler. Due to the nature of HFA a non-contact measurement device is strongly preffered. So far the only non-contact solution that appears to be capable of measuring the various interface levels is a Vega nucleonic density...