  1. TurbineDoctor

    Disposal of waste oil using it as turbine fuel.

    RMW, the deposition was so heavy on the Stage 1 Nozzle that it changed the throat dimension between partitions.
  2. TurbineDoctor

    Offline Water Wash System for F5 GTG

    The Off-Line compressor wash gives you the most "bang for the buck" vis-a-vis performance improvement. In addition to monitoring unit performance, my 36 years of experience with GE gas turbines has shown that a borescope inspection or at least a manual visual inspection through the inlet bell...
  3. TurbineDoctor

    Disposal of waste oil using it as turbine fuel.

    I have had experience with a client who added transformer oil to No. 2 distillate to burn within an MS5001P GE gas turbine. The results were not good. Specifically, wound up with SIGNIFICANT deposits of calcium carbonate inside of the the combustion liners, combustion transition pieces, and...
  4. TurbineDoctor

    Bolting Temperature Ratings

    Thank you very much for your prompt and insightful response!
  5. TurbineDoctor

    Bolting Temperature Ratings

    I'm having problems in finding the recommended temperature ratings for the following bolts; note that I've downloaded the applicable ASTM documents, but found only vague information: N Drawing ASTM Material Head Marking N14 A354 Gr BD Alloy Steel 6...