  1. structuralnerd

    Existing 1950's era building

    Does anyone know if the BOCA code included a 15psf partition load requirement in the early 1950s? I only have access to a 1975 BOCA code, which does have the provision. Thank you in advance.
  2. structuralnerd

    wood framed elevator shaft

    I am designing a two story church where the design/build contractor is requesting to frame the elevator shaft out of wood to save cost. The architect thinks they can make it work per fire code. Does anyone see issues with this structurally as long as you design the wood posts at the rails...
  3. structuralnerd

    Theater Curtain Weight

    Does anyone know how much in psf a typical high school theater curtain weighs? It looks like the velour kind in the existing theater we are remodeling.
  4. structuralnerd

    wood sheathing to cold form studs

    I took a look at IBC 2006 and it looks like they took the tables out, but I saw that it's in the IBC 2000.
  5. structuralnerd

    wood sheathing to cold form studs

    Does anyone know where to find the shear capacities of wood sheathing to cold form studs using screws?
  6. structuralnerd

    Seismic response coefficient Cs

    Can anyone tell me what the seismic response coefficient of a structure means (Cs)? What does it represent? I know that V=CsxW, but does anyone know an explanation for Cs?
  7. structuralnerd

    partially enclosed vs enclosed

    But what if the doors or windows are blown out? I have a call into the International Code Council. I left a message, so when they get back to me I'll let you know.
  8. structuralnerd

    partially enclosed vs enclosed

    I am trying to determine if my large warehouse I am designing is classified as "enclosed" or "partially enclosed." There are some very large overhead doors in the project all in a row along one wall. Do you consider overhead door so be an "opening?"
  9. structuralnerd

    isolated beam

    Does anyone know what the term "isolated beam" means in the ACI 2005 code section 8.10.4?
  10. structuralnerd

    diamond cut in slab around steel column

    This may seem like a very basic questions, but I have specified the standard detail of the diamond cut around a steel column in the concrete slab at the base for almost every steel project. In the diamond cut, we call out to put 1/2" expansion joint, and then a construction or control joint...
  11. structuralnerd

    Concrete deck expansion joint

    I'm designing a 2 level concrete parking deck - post-tensioned beams with a cast-in-place slab spanning between. It is approximately 280 feet long by 180 feet wide. Do you recommend I put an expansion joint in?
  12. structuralnerd

    Plastic Hinges

    Do any of you have any good reading material suggestions about this subject?
  13. structuralnerd

    Plastic Hinges

    Also, when is it required to use plastic design? Which seismic design categories?
  14. structuralnerd

    Plastic Hinges

    I have not done a whole lot of seismic design, so please excuse my ignorant questions. Which beams/columns should you strategically make elastic and which should you make plastic?
  15. structuralnerd

    early concrete loading

    On our structural general notes page for our typical jobs, we usually put a note that says do not load concrete members before 14 days and before their specified 28 day strength is obtained. I have a contractor asking if he can load it before the 14 days. Is there an ACI document that I can...
  16. structuralnerd

    ASCE 7-5 seismic question

    In ASCE 7-05 section 12.4.3, it talkes about including the seismic overstrength factor where conditions require it. When is that factor specifically required, and when do you use the normal seismic equations shown in section 12.4.2?
  17. structuralnerd

    tying new foundation to existing foundation

    What are your thoughts about tying a new building foundation wall to an existing foundation wall if the new building's superstructure is designed so it could stand alone if the existing building were to fall down? Do you recommend doweling or not? Does doweling help settlement issues?
  18. structuralnerd

    Mat foundation

    Does anyone know of a good source of reference/resource for designing mat foundations?
  19. structuralnerd

    Building expansion joint or not?

    Could you do the expansion joint with the double column line and provide a deck angle at each side and treat it like two separate buildings all together? So, no shear transfer through the two buildings? Would the precast panels need to provide an expansion joint as well? What are the issues...
  20. structuralnerd

    brick deflection

    I've been looking through the code, and I cannot find the section in IBC that talks about the 0.7 factor. Can you point me in the right direction? Thanks.