  1. lucino

    LPG Burner-How to minimize consumption?

    Cougarfan, .....are you still looking for answers?...Yes, especially technical ones.However, I was through with the study.My approach is practical. I compare the standard consumption established in the product specifications with the actual consumption. Making the study however was not easy, I...
  2. lucino

    LPG Burner-How to minimize consumption?

    Good day. Dideyjohn: I dont know how to respond technically. But seeing that I have an issue here is well appreciated. As of the moment the oven that I am refering to is actually considered to be retired and replaced with a new one. However there are other dryers and toasters in the factory...
  3. lucino

    240V single phase supply

    Good day ashbeel6. After doing your intention you will have a minimum of 520A single phase supply at 240V which is more than what you require. Except when the three phase side needs stability with respect to load balancing, there is no problem. However, if it warrants, my advice is to use three...
  4. lucino

    chemical feed pump drive

    Good day Tgreif! Motor speed control this these is now becoming simplier by means of Variable Speed Drives (VSD's). I am not familiar with AFDs but I assumed it means Automatic Frequency Drive. If this is the case it is the same as VSD. My experience suggest that AC speed control has more...
  5. lucino

    Flooding in the Substation Area

    Hi Dafo74. My first comment to your post on safety is based on common sense. The second comment is based on experience. Sorry I cannot comment on "touch voltage" you mention. However, I appreciated cuky2000's post. His suggestion is worth considering. For this I give him a star...
  6. lucino

    Flooding in the Substation Area

    Dafo74: Good day! Immediate concern maybe is on safety of personnel that would be servicing the substation. Longterm effect I believe would be moisture that can cause cabling termination deterioration. Future installations maybe should consider concrete platforms higher than expected flood...
  7. lucino

    LPG fueled Burner

    Quark, Now I have the idea how to do with the savings initiative. Your suggestion of recirculating the hot air through moisture removal by desiccant dehumidifier is well taken. I am now downloading the chart you recommend and will be using it after I can gather DB&WB values. Regards. Lucino
  8. lucino

    LPG Burner-How to minimize consumption?

    Dideyjohn, Thank you for the inquiry. I agree that a gage is the ultimate measure of usage. However as of the moment there is none dedicated for the specific oven except for a central flowmeter which measures LPG usage for the whole factory. It would be easier if it has.Anyway,my post is about...
  9. lucino

    Good day to everybody. Presently I

    Hello guys, EraySir: I am still consolidating data. Our generated voltage average is 463 volts while the user side only needs 440 volts. My data is not complete yet. Any progress will be posted. Jghrist: Seems that I have no choice but to approximate distance of loads from generator side. My...
  10. lucino

    LPG fueled Burner

    Quark, Thank you for your never ending assistance to those of us that needed an expertise such as yours. As of the moment I am facilitating the analysis of the moisture content before and after the Oven (Pre Dryer) so that I can have a basis for comparison. The ambient temperature at the exit...
  11. lucino

    LPG fueled Burner

    Quark, Thank you for your comments as immediate as i need. I have yet to explore the internet site you recommend. Anyway, as an added info: Product speed: 1.1 meter per minute Heating chamber length: 10 meters. Incoming Product rate : 450 kg/hr. With the following heating control...
  12. lucino

    LPG Burner-How to minimize consumption?

    Good day. As part of an improvement team created by my company, I am presently making on a study of minimizing LPG usage to an oven using Shellane (LPG with heating value of 49.95 MJ/Kg) as fuel to preheat a food product conveyed inside a chamber with control temperature setting. The oven is a...
  13. lucino

    Good day to everybody. Presently I

    Hello guys, Jbartos: Its a clerical error Va=461.9 Your Ploss calculation is alien to me specially I do not know what value is specific resistance of each segment. Where shall I got it? Can I compute it? If it is computed, can I use the meter reading data or do i need some other data that is...
  14. lucino

    LPG fueled Burner

    Good day. As part of an improvement team created by my company, I am presently making a study of minimizing LPG usage to an oven using Shellane (LPG with heating value of 49.95 MJ/Kg) as fuel to preheat a food product conveyed inside a chamber with a control temperature of 180oC. The oven is a...
  15. lucino

    Good day to everybody. Presently I

    Moturcu, Good day. Yes, now I understand. But our system is a three phase 440 Vac system supplied by three diesel driven generators with one generator having a capacity of 1800KVA. How can I compute for the copper losses in a single line so that I can multiuply it by 3. Our actual data as...
  16. lucino

    Trouble shooting aids.

    Good day. Doing in house repairs at card level makes a lot of sense only if you don't have to troubleshoot which component is defective. Nowadays electronic cards circuitry gets complicated and components smaller which is hard to be replaced without aid of sophiticated tools. Hiring and/or...
  17. lucino

    Good day to everybody. Presently I

    Moturcu: Please expound on item no.1 & 2... Why I have to multiply by 3 and not square root of three. Is it not that 3 phase system calculations involved square root of three? Thanks. I would be indebted. GusD: Yes. I agree with you. Actually the 97% is only for kVAR calculations.In...
  18. lucino

    Flash Steam Heat Recovery

    TBP, Good day. Your comments are well taken. Actually this also a line of thinking I am at the moment considering. I agree with you that recovery projects should be sustainable. Thanks for the input. Lucino
  19. lucino

    Good day to everybody. Presently I

    DanDel, Good morning. Yes I am certain. In fact this is an average of the data I personally and religiously record every hour for successive 24 hours without sleeping. Average Fuel consumption:243 liters Average energy produce :861kW-Hr Therefore the fuel ratio = 243liter/861...
  20. lucino

    Flash Steam Heat Recovery

    Good day Chicopee. I think it is. But I also suspect that one of the steam traps is leaking introducing steam to the condensate tank which in turn leaks to the atmosphere. By this my problem is how to identify this leaking trap because all the condensate lines (about 6 pipes)towards the tank...