Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: ZGuy
  • Order by date
  1. ZGuy

    PDMWorks Ent Block and Attribute names for PDF?

    Thanks Bradley - I gave you a star for that one....probably should have given TheTick one too! I will give what TheTick said a try and see how it goes. I did get a reply from one of the application engineers... >This is a current limitation of PDMWorks® Enterprise and has been reported >to...
  2. ZGuy

    SW2009 SP2.0 x64 & x32 Systems

    Hi Colin, I've always found, in the other programs I run, that a 64 bit version of a program on a 64 bit OS is faster than the 32 bit on a 32bit OS or the 32 bit on a 64 bit OS. Also, with the 64 bit OS you get around the memory address problems and can actually put 8 or 16GB or RAM in a...
  3. ZGuy

    PDMWorks Ent Block and Attribute names for PDF?

    Hi all, I'm trying to finish up my first creation of a Data Card for the file type .pdf. Does anyone know the Block names and Attribute names to get a Data Card to map the Properties from a .pdf file? I have loaded the default data card "all(pdf)_gb.crd," which brings with it the required...
  4. ZGuy

    How do I point FlexLM to correct NIC

    Thanks for the help and replies. I really appreciate your help on this Ben and 'justkeepgiviner' (PTC support just called and confirmed the solution as recommended by 'samoth') Now to see if I can make one installation with a list of different license servers (mine first then clients' 2nd and...
  5. ZGuy

    How do I point FlexLM to correct NIC

    I'm attempting to install FlexLM on my workstation. I have a (legitimate!) license file but when I install the license server (old build WF2, M171) it sees the wrong NIC's MAC address. I have logged a call w/ PTC (call # 5739941) but have not heard from them yet. The knowledge base at PTC...
  6. ZGuy

    Steering rack location

    There may be other considerations, but the first that comes to mind is possibly the desire to have Ackerman affect. The is much easier to do with the rach and hence steering arms aft of the front axle. The need or desire to have partial or full Ackerman is a whole different discusion! ;-)...
  7. ZGuy

    different colour for instances of family

    Only method I ever found that worked was work around from PTC support & as Ed (aka prohow) mentioned above. Create surfaces that use existing geometry to drive (ie surface is a child of solid.) One surface feature for each instance that you want a different color. Control color attribute to...
  8. ZGuy

    .pcf & not selecting correct Laserjet paper tray

    I am creating some new plotter configuration files (.pcf) for users in a remote location. The scaling of the plots appears to work just fine, but the printers are not selecting the correct paper tray. Does anyone know how to make the darned printer pick up the correct paper for the size plot...
  9. ZGuy

    Help locating odd wheels!

    Other sources are Bogart in Santee, CA phone 619.596.7605 (really helpful and flexible when I needed to rebuild some HRE wheels!) http://www.bogartracingwheels.com/ Kodiak Motorsports in Abbotsford, BC, Canada phone 877.856.7311 http://www.kodiakracingwheels.com/ See also Diamond Racing...
  10. ZGuy

    Ghost Objects And Intralink Woe

    Check to make sure that there area no models (parts or assy's) that were members of interchange assy's. The model will have a hidden dependancy to the interchange assy that was not kept. Open to the model that I-Link says is dependant upon the ghost object. Set up - Interchange - Remove If...
Back
Top