Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Haroon Baloch

    Secondary Voltage of Broken Delta VT for 67N Protection of a Grounded Wye System

    @wcaseyharman Thanks a lot for your help. I will check with the PT manufacturer for the overvoltage capability. I believe, in this case, its better to go for line-to-line rated PT 4160/120 since then I wont have to worry about PT saturation during fault and it will also give 120V L-L in Wye-Wye...
  2. Haroon Baloch

    Secondary Voltage of Broken Delta VT for 67N Protection of a Grounded Wye System

    @wcaseyharman This is a dumb question but I just want to be sure: If there are two VTs (single phase) 4.16/sqrt(3) // 120/sqrt(3) and 4.16//120 VT, will we get the same output, that is 120 L-L and 120/sqrt(3) L-N for a 4.16kV system voltage, since the ratio of both VT is same? The only...
  3. Haroon Baloch

    Secondary Voltage of Broken Delta VT for 67N Protection of a Grounded Wye System

    @wcaseyharman You are right, I get it now. I was wrong about the second point VLN is not the rated voltage of the VT. It is the VT secondary voltage under normal(un-faulted) condition. So if we choose 4160 // 120/sqrt(3) = 4160 / 69 VT then under normal operation VLN = 69/sqrt(3) and under fault...
  4. Haroon Baloch

    Secondary Voltage of Broken Delta VT for 67N Protection of a Grounded Wye System

    @wcaseyharman I kinda get what you're saying, but its a bit confusing, so below is my step by step approach. Let me know where I am going wrong. - The Broken Delta output is 3V0. - VLN is the rated secondary voltage of the single phase VT. - For a resistively grounded system during ground fault...
  5. Haroon Baloch

    Secondary Voltage of Broken Delta VT for 67N Protection of a Grounded Wye System

    @wcaseyharman The resistance of the NER is 24 Ohms. Also, even if I am rating the VT for line-to-line, it should be 4160/120V, since during fault 3V0= 3VLN. So I need the secondary line-to-neutral output (VLN) of each VT to be 120V.
  6. Haroon Baloch

    Secondary Voltage of Broken Delta VT for 67N Protection of a Grounded Wye System

    @wcaseyharman My system is also resistively grounded Wye. It's resistively grounded via a Neutral Earthing Resistor. Does it change anything, whether the system is solidly grounded or resistively grounded? There are conflicting answers here on whether the VT should be line-to-line rated or...
  7. Haroon Baloch

    Secondary Voltage of Broken Delta VT for 67N Protection of a Grounded Wye System

    @waross You're right. The VTs are rated line-to-neutral and connected in Wye Grounded on the primary side. I went for line to neutral since the system is Wye grounded. I suppose if it was Delta ungrounded then i would have to choose line to line rated VTs, correct me if i'm wrong. Also, let me...
  8. Haroon Baloch

    Secondary Voltage of Broken Delta VT for 67N Protection of a Grounded Wye System

    I'm working on a 4.16kV, 40kA-3sec, 4000A Switchboard. We need Directional Earth Fault (67N) protection on the Generators. The relay manual (Siemens 7SR2..) mentions that the polarizing quantity for the directional protection can be "calculated from the 3 phase voltage inputs or the 3Vo input"...
  9. Haroon Baloch

    What does "Neutral Protection of 50%, or 100%, of the phase setting" in ABB MCCBs mean?

    In all 4-pole ABB MCCBs, above a certain range, it is mentioned that that there is an option to choose 50% or 100% Neutral protection. Specifically, it says "The four-pole circuit-breakers are always supplied with the neutral protected by the trip unit and with protection of the neutral at 100%...

Part and Inventory Search