  1. chuckd83

    Transformer rating when power flow direction may change

    I've answered my own question. I came across a nameplate that instead of "STEP DOWN" or "STEP UP", it said "STEP UP / STEP DOWN". So I assume the transformer was rated for bidirectional flow. And this needs to be included in any transformer spec for BESS.
  2. chuckd83

    Transformer rating when power flow direction may change

    2) When we refer to a 50 MVA-rated transformer in IEEE World, we are discussing the transformer's output. Correct. Wouldn't the transformer be manufactured such that the output winding is rated for 50 MVA and the input winding is rated for 50 MVA + losses? My question is what if the input and...
  3. chuckd83

    Transformer rating when power flow direction may change

    C57.12.00 Section 5.4.1 states: The rated kVA of a transformer shall be the output that can be delivered for the time specified at rated secondary voltage and rated frequency without exceeding the specified temperature-rise limitations under prescribed conditions of test, and within the limits...
  4. chuckd83

    Relay pickup above breaker continuous rating allowed

    In the medium voltage world, we set our pickup above equipment ratings to allow the customer the flexibility of temporary overloads. We protect against short-circuit and not overload. For cable, this is allowed per NEC 240.101(A). For transformers, NEC Table 450.3(A). Is this discussed...
  5. chuckd83

    Precast Trench Ampacity

    jghrist, sounds like the same as IEC 60287. I've read BS 7671 has a correction factor. Does anyone know it or is it a table? I know it only applies to LV cables.
  6. chuckd83

    Precast Trench Ampacity

    cuky2000, the software I have (ETAP & SKM) cannot create such a model. I believe CYME does it, but it's a $30k software. I come across this maybe once a year and cannot justify the cost. I skimmed through those studies you mentioned (Trenwa sent them to me). I didn't find anything that useful in...
  7. chuckd83

    Precast Trench Ampacity

    From my research, there is no ANSI standard to determine the ampacity of cables installed in a precast trench with solid, unventilated covers. I did find that IEC 60287-2-1 Section 4.2.6 has a method, but don't have the standard available. What do you use? I have ETAP to calculate the ampacity...
  8. chuckd83

    Cable critical moisture content

    In order to calculate the cable ampacity for buried cables, the thermal resistivity needs to be determined. This is heavily dependent on the moisture content of the soil which varies. IEEE 442 Annex F has information on determining the "critical moisture content": "The critical moisture...
  9. chuckd83

    In an arc flash calc at an MCC - do you "Include Main" or "Exclude Main"?

    Yes, essentially you have to determine if an arc occurs downstream, does it have the capability of migrating to the line side of the main breaker. Your client says yes, it does. Or they simply want the entire MCC labeled the same in order to prevent confusion for those selecting the appropriate PPE.
  10. chuckd83

    user dauwerda

    Thanks. Those are the equations I extracted. I took it from your post back in January that they were taken from IEEE 738. Thanks for the sources.
  11. chuckd83

    user dauwerda

    I'm sorry, I can't seem to find a way to private message someone and the thread they posted on is closed. dauwerda, You posted a spreadsheet calculator on the below thread for the deratings of bundled conductors. I extracted the equations from the spreadsheet, but can't seem to find them in...
  12. chuckd83

    selecting an appropriate thermal resistivity for underground cable calculations (with soil test)

    @7anoter4 I tried to PM you, but I don't see that option. Can you quote the relevant section in that standard? Our IHS subscription does not include it and it's $350 to purchase.
  13. chuckd83

    selecting an appropriate thermal resistivity for underground cable calculations (with soil test)

    I cross posted this on the electrical forum, but thought some soil engineers could help. An underground cable ampacity study comes across my desk every month or so. The thermal resistivity of the soil (rho) has a fairly significant impact on the ampacity of the cable and it's always a question...
  14. chuckd83

    selecting an appropriate thermal resistivity for underground cable calculations (with soil test)

    An underground cable ampacity study comes across my desk every month or so. The thermal resistivity of the soil (rho) has a fairly significant impact on the ampacity of the cable and it's always a question of what to use. With no soil test, I use a rho of 90 degC-cm/W unless it is in the desert...
  15. chuckd83

    Fire pump ground protection - NEC 695.6(G)

    Thanks for the replies. I think you’re right the the entire substation cannot trip for a ground fault. Maybe a possible solution is to make it high resistance grounded.
  16. chuckd83

    Fire pump ground protection - NEC 695.6(G)

    NEC 695.6(G) states "Ground-fault protection of equipment shall not be installed in any fire pump power circuit." Does this include upstream ground-fault protection all the way to the transformer? This would remove ground-fault protection from all other equipment fed from the substation. Or is...
  17. chuckd83

    Motor torque curves

    I was given a motor data sheet from the 90's that includes speed vs. current, power factor, average torque @ 100% and 90% V, load torque, and oscillating torque @ 100% and 90% V. What are the oscillating torque curves? I've never heard of that.
  18. chuckd83

    How to find buried delta winding current using symmetrical components

    That is given by Zpt% in the Westinghouse equations.
  19. chuckd83

    How to find buried delta winding current using symmetrical components

    My notes showing the sequence network interconnection for a fault on the primary.https://files.engineering.com/getfile.aspx?folder=40ec260a-bdcc-405d-b682-7cde23880aad&file=notes.jpg