Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Ratheesh_n

    Stellite 6 over Alloy 625 weld overlay

    Members, We have a case of valve disc material F44 and its weld overlaid with alloy 625(NICrMo3) and followed by weld overlaid with Stellite 6. 1. Is it a recommended method to follow and what must be the reason for doing the corrosion resistance overlay before hard facing. 2. What is the...
  2. Ratheesh_n

    Hard face over alloy 625 weld overlay

    Members, We have a case of valve disc material F44 and its weld overlaid with alloy 625(NICrMo3) and followed by weld overlaid with Stellite 6. Is it a recommended method to follow and what must be the reason for doing the corrosion resistance overlay before hard facing.
  3. Ratheesh_n

    Corrosion test for UNS 31254 in fittings vs forged flanges.

    @SJones Requirement is same for all contractors and vendors. So, it's not related to the quality of contractor/vendor. Thats what the reason we wanted to know the metallurgical background.
  4. Ratheesh_n

    Corrosion test for UNS 31254 in fittings vs forged flanges.

    @EdStainless test temperature is 50 deg for both the cases. surfaces of the specimens is in the “as delivered” condition for testing.
  5. Ratheesh_n

    Corrosion test for UNS 31254 in fittings vs forged flanges.

    Members, One of client specification mentioned corrosion test G48 method A with duration of 24 hours for forged flanges for UNS 31254 material. But for same UNS 31254 fittings(formed from pipe or plate) G48 method A with duration of 48 hours. Please tell why there is a difference in the...
  6. Ratheesh_n

    Power failure during PWHT

    @ weldstan, Interruption happened during heating cycle.
  7. Ratheesh_n

    Power failure during PWHT

    Dear Team, Power failure happened during heating cycle of PWHT of APL 5L X65 welds ( piping as per B31.3).understand there is no issue in re-doing the PWHT as the crystal transformation temperature is not reached. 1). Does this interruption will have any impact on metallurgy ? 2). What is...
  8. Ratheesh_n

    Impact of using SS wire brush over the Inconel welds - any chances of rust spots generation ?

    Team, One of our vendor has claimed that usage of zirconia grinder is recommended over Inconel material as it will not result in the change in surface chemical composition. Would like to get your view on this
  9. Ratheesh_n

    Zirconia Grinder imapct on chemical composition of material

    Dear Team, We have to PMI of Inconel forged material (ASTM B564) with spectro. After the PMI the burn damage due to PMI need to be removed by Grinding. So vendor has proposed grinding with Zirconia grinder in order to avoid the change in chemical composition of material Surface. So please...
  10. Ratheesh_n

    Impact of using SS wire brush over the Inconel welds - any chances of rust spots generation ?

    Dear EdStainless, Some clients specifies to do pickling as per ASTM A 380. But ASTM A 380,its applicable for stainless steel. So its not mandatorily doing by all manufacturers, but following as a recommended one. Client also recommended to follow this whenever the surface contaminations found...
  11. Ratheesh_n

    Impact of using SS wire brush over the Inconel welds - any chances of rust spots generation ?

    @EdStainless Thanks.. i would like to add the back ground for this case which will have more clarity on my query. We have fabricated Inconel spools from our shop and shipped to field with proper preservations. During the site fabrications ,we found rust spots in root side of the weld in...
  12. Ratheesh_n

    Impact of using SS wire brush over the Inconel welds - any chances of rust spots generation ?

    @kingnero Concern is not the type of stainless steel wire brush used. Concern here is what is the impact if we use SS wire brush on Inconel as iron content is more in the ss compare to Inconel.
  13. Ratheesh_n

    Impact of using SS wire brush over the Inconel welds - any chances of rust spots generation ?

    Dear team, As we know use of CS wire brush over SS and inconel welds are not preferable as it will lead to contamination and rust spots generation. Similarly what will the impact of using ss wire brush over Inconel welds ? Weld :- Inconel 625 Regards, Ratheesh N
  14. Ratheesh_n

    Heat treatment requirement of F468 grade 625 after manufacturing by rolling

    F468 doesnt state the stage of heat treatment .. Concern is the impact of metallurgy and mechanical properties after rolling operation .So did the re-heat treatment is required ...
  15. Ratheesh_n

    Heat treatment requirement of F468 grade 625 after manufacturing by rolling

    Dear Team, F468 grade 625 manufactured by rolling operation and heat treatment (annealing) done on the bar prior to manufacture of studs. No annealing done after the rolling operation is completed. Is it acceptable Regards, Ratheesh
  16. Ratheesh_n

    simulated heat treatment requirement for API 5L X65QS/X65QO SAW pipes for nace service

    Dear All, We have received input from manufacturer that the SAW pipe test coupons are doing simulated PWHT prior to MPQT as per API 5L.Please let us know why this simulated PWHT is doing for test coupon and whether this is required as per standard Regards, Ratheesh N +918451991305
  17. Ratheesh_n

    Difference between ANSI FCI 70-2 & 70-3

    HI, can anyone please provide ANSI FCI 70-3 standard or explain what is difffernce between these two standards Thanks, Ratheesh N
  18. Ratheesh_n

    PR2 test requirement with respect to operating cycles -- API 6A

    Dear All, Please let us know what is the meaning of operating cycle mentioned in API 6A.table 57 refer PR2 for 200 operating cycle.what is the meaning fir this .. please help