hi there , I'm happy to tell you that I finally managed to finish this minor overhauling job. I did the following:
1- replaced the Journal bearing ( DE ) .
2- replaced the combined ( journal/thrust bearing) (NDE).
3- replaced the main oil pump ( MOP) which i discovered that it...
Maybe I did not mentioned the story behind all of this which I'm still digging it because i just joined this plant 1 month ago and I'm struggling to get history about this issue.
I found an investigation report said this :
on July 2018 ,The blower main oil pump had a major failure.
it was...
update :
the shaft is too heavy to push !!
we are dying to reach 0.45mm ( required axial float .
the location is too small you cannot fit your body and push.
i got 2 guys , one big strong Indian guy and another small Filipino guy ( who is also very good rotating machines guy ), but i need...
UPDATE:
we found the thrust bearing pads white metal melted away.
we are suspecting our main oil pump is having internal damage , looking to the oil pressure trends , the oil pressure dropped before the trip and the bearing temp , went to 110 degree C.
now we are stuck up after replacing the...
quick update :
axial float found 1.6mm
old info : bearing temp went to 119 deg. C during the trip .
also old info : lube oil pump pressure dropped to low level before the trip.
so we are assuming thrust bearing failure.( maybe the journal as well )
We are planning to open the bearings and...
Thank you so much for your support guys ! tomorrow we are going to drop the coupling & measure the axial float . I will tell you about the findings ,,,
Hi all ,
i have a problem in one of our Plant centrifugal blowers , when it was stopped it gave a HH alarm for axial displacement.
can anyone help me to know what could be the root cause for this problem ??
The blower was offline for around 1.5 months for some low lube oil pressure then oil...