Its not thermal mass effect and both set points are the same.
I guess surface convection cause this negative load but I dont get the physics behind its calculation .
This is the heat gain graph through floor for summer design day. The point is that, air temperature is less than surface...
Hi
I have modeled a 8-storey building in designbuilder software. there is a the problem in its cooling load report; The report indicates heat transfer in middle floors which are located between 2 conditioned spaces. I made the software to ignore thermal mass effect. Is it a bug in the software...
hi guys
I have a problem with my pressure regulating landing valve.When i close nozzle and open landing valve, the connection will get out the its place:
But all of a sudden, in one of the fire cabinets, the air vent open and a little air comes out, then the connection stays in its place...
hi guys
i have a problem with my design and i will appreciate if anyone can help me.
i have a room in basement, that has high humid weather. its a residential room. is it possible to use exhaust fan for reducing humidity? if yes, how many ACH should i take?
hi guys;
Is there any approval (like fm ,ul or lpcb) or standard code for salt spray test for fire alarm systems? I live in an island with 85% humidity which seawater causes corrosion in fire alarm devices which have lpcb approvals.
hi guys;
Which kind of smoke/heat detectors is suggested in high humidity weather? I'm working in an Island which humidity have destructive effects on detectors, and after a period of time make false alarms.
tnx UFT12;
There is another clause which is said:
E.4.6:......For fires in flammable liquids of appreciable depth, a Class
B fire extinguisher is provided on the basis of two numerical
units of Class B extinguishing potential per 1 ft2 (0.0929 m2)
of flammable liquid surface for the largest...
hi guys;
I have a petroleum factory which is stored flammable liquids in tanks. There is a table in NPFA10 that tell us the fire extinguisher size and placement for class B fire.
But also there is paragraph which is said:
6.3.2.3 For flammable liquid hazards of appreciable depth, a
Class B...
hi guys
I want to choose pipe sizes for fire sprinkler system. The Hazan-Williams formula have flow rate, pressure loss and pipe diameter. For determining the pipe diameter, the value of flow rate and pressure loss have to be known. We have flow rate from the required flow rate for each...
tnx UFT12
I guess the clause you mentioned is :
A.8.15.1.2.1 Minor quantities of combustible materials such
as but not limited to cabling, nonmetallic plumbing piping,
nonstructural wood, and so forth can be present in concealed
spaces constructed of limited or noncombustible materials
but...
tnx cdafd
8.15.1.2.1* Concealed spaces of noncombustible and limited combustible construction with minimal combustible loading having no access shall not require sprinkler protection.
what does "having no access" mean? Drop ceiling usually have access through removing tiles.
Hi guys
Its about 5 days that Im researching about sprinkler above drop ceiling but I can decide its a mandatory to install sprinkler above drop ceiling or not. In NFPA there are a few clauses about drop ceiling.
8.15.23 Spaces Above Ceilings.
8.15.23.1 Where spaces have ceilings that are lower...