  1. bearjew

    Programming Shear and Moment Diagrams

    Thanks for the replies everyone.
  2. bearjew

    Programming Shear and Moment Diagrams

    I wrote some software in Python that basically analyzes any beam that the user enters and determines support reactions/deflections. I accomplish this using stiffness matrices. However now I want to be able to draw the shear, moment, and deflection diagrams for the same beam. I could probably...
  3. bearjew

    Frame Drift Question

    JAE, thats fair. I just have had trouble getting drift to check on multi-story moment frames with brittle cladding in the past when using 50-year interval. If you have a braced frame or shear walls I doubt its an issue.
  4. bearjew

    Frame Drift Question

    I meant to say 50-year seems like overkill, typed 5-year instead lol. But interesting. That's above and beyond.
  5. bearjew

    Frame Drift Question

    What do you typically use instead? IMHO, using true 50-year wind for serviceability seems like overkill.
  6. bearjew

    Warehouse Slab Design - Dowel-less joints

    Can anyone explain to a young engineer WHY dowels are used at control/contraction joints? In my experience, we, like MotorCity, have only used them at construction or cold joints. All of our control joints are sawn to 1/4 of the slab thickness, with the reinforcing continuous through it (most...
  7. bearjew

    Decking with Heavy Loads

    Assuming a 3-span condition, I think you can accomplish 700psf + DL with 8" slab over 3" NC decking. WWF likely wont suffice though. You'll probably need (2) layers of #4 bars @ 12". And you'll have some very heavy steel below depending on the spans, but thats where I'd start anyways.
  8. bearjew

    Decking with Heavy Loads

    ...Metal decking alone or with concrete topping? Composite action or non composite?
  9. bearjew

    Scissor Man-Lift on Mezzanine

    Your note looks like a good compromise, provided your precast supplier reads it. We typically design elevated slabs on metal deck over bar joints. Design load is 125psf majority of the time. Reinforcing is welded wire fabric. What we have noticed, is given these conditions, if you run thru the...
  10. bearjew

    why is that? (bracing question)

    You may get results closer to what you expect if you apply a uniformly distributed axial load to the collector elements instead of a single point load at one or either end of the frame. This would more correctly model how a diaphragm is distributing load anyways.
  11. bearjew

    Load Distribution Theory

    This is a fair argument, and I agree. If this is the only answer I receive, I accept it just fine. I just know that there are a lot of people here who understand structural analysis much more so than myself. I did some searching on this forum for this question before posting, and some...
  12. bearjew

    Load Distribution Theory

    For a rigid diaphragm, I would agree that a typical floor has mostly the same size joists/beams, so equal stiffness and the tributary area method holds water. I'm curious the argument for when girders come into play or weird framing such as if you have a lot of floor openings. For a flexible...
  13. bearjew

    Load Distribution Theory

    Hi all, When modeling uniformly applied gravity loads to a structure, engineers often distribute them based upon tributary area. However, I have been thinking, whats the theory behind this? Wouldn't a steel deck behave as a flexural member and distribute load to supporting members via beam...
  14. bearjew

    Service Wind Speed Drift ASCE 7-16 Load Combination

    I'm not sure about ASCE 7-16, but in 7-10 I usually design for drift by using (0.7)(0.6)=0.42 for my wind load factor. The 0.7 is recommended per AISC design guide 3 for a 10-year recurrence interval and the 0.6 is because I design using ASD. Obviously if you design using ultimate loads you'd...
  15. bearjew

    Beam stability against LTB

    Would this approach also work for checking a lifting beam for LTB?
  16. bearjew

    Cruciform LTB

    I'm sorry, I don't follow. How would battening together the flange tips not provide LTB restraint in this case? It may be old school, but I've always been told that only 2% of the compression flange force is required to classify as lateral bracing. You must've had some incredible loads to not be...
  17. bearjew

    Short Pier

    Could you not just reduce the capacity of your vertical bars by the ratio of (development provided/full development)? Why does ACI require the verticals to be fully developed for shear transfer here? Although you may not get much out of them considering your pier is only 6" in this case.
  18. bearjew

    Laced Column Design

    Thank you for your response. You're correct, the crane column likely does not need to be fixed. Regarding the lacing design, I do remember reading in DG7 that fabricators prefer W-shapes to the lacing angles. This ship has not sailed yet so I have time to explore alternatives. Do you have any...
  19. bearjew

    Laced Column Design

    Please see the attached for a screenshot of my RISA model.http://files.engineering.com/getfile.aspx?folder=dda28a04-46ba-4b1d-97e7-a78b41af82ad&file=laced_columns.PNG
  20. bearjew

    Laced Column Design

    Hi everyone. I am in the process of designing a laced column system for a new bldg. The new bldg houses a magnet crane, and we are to follow TR13 requirements for the design of its support. I have available to me AISC DG7, AISE TR13, and ASCE "Structural Design of Industrial Buildings", all of...