Using my local nomenclature, the Z would indicate a critical and piloted safety function of the valve. So a motorized PVV with a safety role.
Which would make it a pressure control valve and not a (purely mechanical) pvv.
However there are as many nomenclatures as they are sites.
It may just...
The European PED, so far as I understand it, does not require the systematice relief devices. It just gives some requirements if you fit one.
The basis of safety is left to the user. If you are not handling any flammable/reactive materials, you can rely purely on having design pressures (MAWP)...
1. Yes, at least in Europe, provinding that:
0. your "reasonable" fire duration is at least one hour (recommended) and covers: fire built-up, detection, emergency response team arrival, first emergency assessment & response, evacuation of personnel & population potentially affected in...
Fictitious velocity in gaseous phase: 3.36m/s
Fictitious velocity in liquid phase: 0.36m/s
Supposing a homogenous mixture without any interaction, the velocity in your pipe would be 3.73m/s
But this inquiry should not get any reply. With the data given, the answer will always be...
The ^0.82 in API 521 is there to account for incomplete flame impigement on the vessel wall.
Depending on the layout and geometries, you may have to challenge that ^0.82 (e.g. take ^1 for small cross-section vertical equipments)
So inherently, method 1 is the way to write it down.
My proposal to complete/explicit a bit more your workflowhttp://files.engineering.com/getfile.aspx?folder=2cdf5628-2a91-473b-893e-6c19e1fe3d91&file=Decommissioning_work_Flow.docx
The worst Kre I've seen for rupture disk is 5.6 (composite disks from Schlessinger).
Be careful with using the 'default' value. I personnaly consider 3 by defualt for metallic disks, 1.5 for graphite ones, and 5.6 for composite ones.
Liquid ring vacuum pumps are essentially volumetric pumps. The capacity changes because of the suction pressure itself.
Use your measured pressure to get the capacity (in Nm3/h for example - which is in effect a mass flow unit).
Your actual volume flow (in Am3/h or effective m3/h) remains the...
Going,
there exist weighted level 'floaters' for level or liquid/liquid level measurement. Those use either articulated arms (I would not recommend those) or piston/telescopic rods.
Our supplier is Bilfinger Berger Industrial Services. Their devices are specifically made to the service (length...
Level measurement may not be the only way around your pumping issue.
Would the apparent density of the slurry be correlated to the sand buildup? If it is, you may be able to simply use a vibrating blade density probe upstream the pump in the pipe if the speed is enough to prevent clogging the...
If you are using atmospheric air you should reduce the relative humidity of your air if it's high (condense it then heat up the air) to preventadsorbing too much water on the carbon
That's vague...
Based on your 8 words sentence, barring mechanical issues and corrosion, I would say:
overfilling
overpressured
underpressured
wrong material
contamination
excess heat (from heating, reaction or heating medium leak) and its reverse
Old thread with info
For liquid that could not vaporize given the conditions and would not flash when relieved, we considered 250 liters as the maximum blocked-in liquid volume in pipes exposed to sunlight before installing a thermal relief valve
We had a liquid expansion coefficient limit to...
I agree BigInch. But a recovery system is different from a treatment system...
The AP42 material linked by TD2K seems quite substantial. Thank you!
Any addition of benzene to the tank will generate an emission of nitrogen+VOC load to your VRU. Your mass balance for the unit should be enough to...
unless you are storing the benzene at high temperature, I don't think a recovery system would be financially beneficial.
Consider that.
You may have to switch to simple emission control by ad- or absorption, or incineration.
with PPM = mg / Litre
1 PTB =2.8530 PPM
1 PPM =0.3505 PTB
That's a factor 3 in efficiency. So as poli60 said, achievable with a 2-stage desalter scheme.
It also applies to exothermal reactions, decompositions, anything that may makes your liquid foam and have a biphasic relief stream at the relief device inlet.