  1. ietech12

    Anyone know what make of gauge this is?

    Take alook at this website, I maybe what you are looking for. http://www.gageitinc.com/sprinkler.php
  2. ietech12

    I need your help_level transmitter_DP type

    How long as it been since the vessel was been cleaned. If both devices share the similar issue I can assume that it may be as simple as plugged taps. If the lower nozzle is located directly under the vessel or close the bottom of the vessel, you may have pookie (What the techs refer to as...
  3. ietech12

    oil-water level measurement

    I will have to agree with roydm on this one and thanks for quick specific gravity lesson. Zdas04 the DP meter is the common choice for interface levels. The other common choice are displacer levels, the old mechanical prehistoric reliable means of interface measurement. Radars are percieved as...
  4. ietech12

    Actuators

    I am assuming you are using a rack and pinion type actuator for on / off control. The three way valve is a standards practice for single port actuation. So the solenoid valve will have port 2 for air supply, port 1 for inlet supply to actuator and port 3 for the exhaust. when the solenoid is...
  5. ietech12

    Level Measurement Standards

    Apologies, The American Petroleum Institute (API) is where you will find most of your information. API will provide procedures for the installation of the more generally used measuring and control instruments and related accessories, as quoted from the website. Also, you can look up vendor...
  6. ietech12

    known issues with 3051 electronic modules

    I would send the modules to emerson for a failure analysis. They would be interested in knowing how it failed as well. At one time emerson had an issue with 3051 models that had the lighting protection module added to the terminal block. The D/A board as also had issues. Example would be that...
  7. ietech12

    Level Measurement Standards

    I have worked in the petrochemical industry for several decades. With new technology for instance smart instrumentation and even smarter fieldbus digital instrumentation I still find myself having to scratch my head to remember basic level calculation. Try this application tool. Here's a demo...
  8. ietech12

    Anyone know what make of gauge this is?

    zflee. You did not provide much information, but I assume that you are dealing with a common fire system where the media would be water. I also assume that you would be dealing with building fire systems of unit deluge fire systems. Either way I am going to suggest ashcroft guages. They are a...