  1. mjohnqa

    Modelling Reactor Process on HYSYS

    Never ever encountered and more over it is very difficult to check the problem without having the Hysys file. If you could share may be we could have a look. Regards, John
  2. mjohnqa

    ESD Forced/ ESD MOS

    ESD MOS is a built-in switch provided in the DCS to enable maintenance of trip transmitters/system so as to avoid inadvertent trip of the plant/unit. Normally the overridden trips gets back to normal after a period of time say 8 hours. Regards, John
  3. mjohnqa

    API 616 Section 5.4.4.3 The fuel co

    good observation. seems like it is not strictly followed everywhere. here too in my company frame-6 GE machine is have an actuated valve (of isolation and maintenance) located outside the enclosure of the turbine, but it is not having a local manual mechanical device for tripping.
  4. mjohnqa

    Learning LOTO plans using P&IDs

    make sure that all the valves (whether control, on-off, relief, isolation) whatsoever the size is should be tagged. apart from this i do not think there is LOTO things you need to include in your P&ID. LOTO procedure is usually a standard safety procedure available with all companies and also...
  5. mjohnqa

    Cooling Tower Cell Arrangement Design

    just two points: 1)it is better to use 2 rows only as this not only enables ample air to circulate it also saves a lot in maintenance, as it may required heavier cranes to reach on top near to the middle row. 2) no. of cells can be optimized by using more blades per fan and hence the total...
  6. mjohnqa

    GT's Air Coalescing Filters

    dear all, we are also facing almost similar problems. we (in middle east) recently commissioned 2 nos. of Frame-6 GE machines 10 months ago and we have started getting HIGH FILTER DP alarms which has forced several times to reduce the load. on investigation we found that apart from the base...
  7. mjohnqa

    Salt deposiotion on and around seawater cooling tower?

    Exacly as said by TD2K, this usually happens during high humid climates. However changing to fresh water is not a feasible solution as the cost of production of fresh/desalinated water is very high and proximity of sea is an added advantage. The vendor of the cooling tower has guaranteed a drift...
  8. mjohnqa

    Salt deposiotion on and around seawater cooling tower?

    we have recently commissioned a seawater cooling tower in the middle east region with a heat duty of 1305MW. This is achieved through a circulation of 120,800t/h of ciruculatiion of seawater. However we have noticed that during high humidity seasons, there is high salt deposit on and around the...