  1. saleda

    Acetone Vapor pressure vs boiling point

    Dear Latexman Now that is what confusing me.... If you have refered to the data I have typed above then as the reading in Gauge decreses with that boiling point decreases, then why should I install heavy Vacuum Pump and achieve maximum vacuum achiievable. At 680 mmHg boiling is at 50-55 oC At...
  2. saleda

    Acetone Vapor pressure vs boiling point

    then what should be the reading at pressure gauge to boil the acetone at 40 oC ?
  3. saleda

    Acetone Vapor pressure vs boiling point

    The following data is of Acetone Boiling Point at different pessures. -59.4 1 torr -40.5 5 torr -31.1 10 torr -9.4 40 torr -2 60 torr 7.7 100 torr 22.7 200 torr 39.5 400 torr 46 500 torr 51 600 torr 55 700 torr At my location ATM pressure is 727 mmHg. when...
  4. saleda

    acetone latent heat at reduced pressure

    Dear ione, Your result shows lower Hvap value than at ATM pressure. whereas it should increse. My calculation results 125.82 cal/gm at 680 mmHg than 124.3 cal/gm at ATM. Plz validate. Thanks, Saleda
  5. saleda

    acetone latent heat at reduced pressure

    Dear All I wanted to know the latent heat of vaporization of acetone at 680mmHg for my condenser design, but could not find it. as latent heat decreases with increase in pressure and vice versa. would somebody refer to some source or provide related equation. Thanks Saleda
  6. saleda

    Reflux condenser with steam / lean air / toluene vapor feeding

    toluene and water will surely azeotrope. http://en.wikipedia.org/wiki/Azeotrope_(data)
  7. saleda

    condenser parallel or series

    sorry TD2K, in our solvent rcovery process intailly we have only one vacuum tray drier for what condenser was designed , now second smaller dryer is installed. which resulted in more vapor flow and loss of acetone that jumped condenser. now rather that manufacturing and designing new condenser...
  8. saleda

    condenser parallel or series

    hi all what arrangement of new same size condenser is better while condensing acetone vapors of what 20 percent jump 1st condenser. thanx
  9. saleda

    PVRV

    in industries that have to deal with highly flammable liquids first and most necesssry task is to to eliminate the ignition source. proper earthing for reducing static charge risk. and the vent of tank can have condenser with appropiate utility running to keep vapor below LEL.
  10. saleda

    How to recover used nitrogen

    we also use liquid nitrogen in our process to have -92 deg C temp. and nitrogen is vented in atmosphere. particularly for we don't have any application for it. but i hope u can repressurize it and reuse it.
  11. saleda

    acetone vapor flow rate control

    Dear all we try to recover acetone from solid material that is being dried in vacuum tray driers. at min. 600 mmhg and 50-55 deg c range. there are 2 such driers where batches are charged at uncotrollable times. when tem and vac is applied intially high load of vapors will vaporize...
  12. saleda

    sodium oxalate solubilty

    y don't u try hot water. solubilty increass considerabily.
  13. saleda

    flow rate control for acetone reovery

    Dear all we try to recover acetone from solid material that is being dried in vacuum tray driers. at min. 600 mmhg and 50-55 deg c range. there are 2 such driers where batches are charged at uncotrollable times. when tem and vac is applied intially high load of vapors will vaporize...
  14. saleda

    Steam Hammer Issue in Reboilers/Condensate

    you should first run your system without vacuum let it run in reflux for some time then apply vacuum , problem will be resolved.
  15. saleda

    Sticky material Separation and Disposal

    you can separate that in centrifuge or nutche filters.