I need find a book that detail or show a drawing of the element in every kind of joist
for example a drawing of the 10K1 or the 28K9 (the top chord and the bottom chord)
thanks for your help
cris
hi everybody
I'm designing a building where the beams in the secundary direction fail by lb/ry>0.17 E/fy i cannot undertand why a secondary member required a section higher than the principal.
you can see the image i'm using etabs, and intermediate design for a building with 7 story
if i...
I need hear your experience about what system can be more economic than a tilt up system (tiltup walls and steel roof)
for a building with 6,000 m2 and hight of 14 m with one only floor.
sory my bad english
thanks in advance
Hi
I have a structure with a irregular distribution i'm using a steel deck like roof
i usually use colector beam in my projects, but in this case, i need other option
i was checking the SDI manual, but in all the examples a collector is the only solution that they use
i want to now your...
hi everybody
i have a structure with 46 ft of clean span i'm using steel beam W24X68 @ 6.5 ft with a steel deck with 2 inch of concrete (composite section)
the live load is 105 lb/ft2, all is checking (deflection, flexure and shear) but i feel this section w24x68 very small for this span
what...
I have the attached condition a slurry wall with a basement that will like the image in the final step before the construction of the last floor only restriened by the pasive force in the bottom
whats must be my equation to know the deep under the third soil and know the moments and shear for...
Hi i need help with the tilt up wall design
rules or tables of experts that work every day, in this area
my projects are industrial building with one only floor
what design method your prefer? aci , slender method ..?
i have this questions little confuses
- whats are the minimum ratios of...
i have a epoxy with the following specifications
tensile strength = 3135 psi
bond strength = 7370 psi
how i must calculate the maximun tensile force for a bar with a diameter 1 1/4
that will be embebed to the concrete
cris
I will use a membrane as you recommend
but there is no way to ensure that the cracks do not appear?
because the supervisor is very strict with this
perhaps with fibers,
what do you think?
Sorry
Here again the explanation more Detailed
I have the rooftop of a parking building with a structural concrete slab (working in one direction) with 5 inches
of thickness and span of 10 feets, supported by beams 76x152 inches the total area is 25,000 square feet
I want to place over this...
Hi
I'm designing a toppping concrete (3 inches) on a slab (5 inches) but do not want that the topping crack that tips should I take the time to build
the slab is built
and the surface are floated
I have no snow effects
And whats would be cut widths if i have a topping of (3 inches)
thanks