Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Drapes

    Cantilevered Concrete Deep Beam - Hanger Reinforcement

    Ive got a cantilevered conc deep beam with a backspan (2x stories high), and will be providing hanger reinforcement along the cantilevered section, running vertically up from the lowermost slab to the next level. Can this hanger reinforcement be lapped or does it need to have couplers...
  2. Drapes

    Section 6.2.3 Robustness - Minimum Lateral Resistance of Connections & Ties

    Thanks Agent666, appreciate it. Do you have any thoughts on my second query re: justifying the load path without any supplementary tie reinforcement?
  3. Drapes

    Section 6.2.3 Robustness - Minimum Lateral Resistance of Connections & Ties

    As I have understood then, in summary - The minimum lateral connection at the interface b/w the wall and slab (considering floor load only) is given by: 5% of G+Q_combination for robustness 3% of G+0.3Q for seismic And minimum lateral connection to justify lateral bracing or restraint at the...
  4. Drapes

    Slender Column Design - Reinforcement Joggle

    Also thanks KootK, missed your response!
  5. Drapes

    Slender Column Design - Reinforcement Joggle

    Thanks steveh49 and slickdeals. In our case, the slender column design has been based on single curvature and minimum moments, which are the governing moments at the ends of the column. An effective length factor ke<1 has been adopted. When combined axial plus moment are assessed at mid-height...
  6. Drapes

    Slender Column Design - Reinforcement Joggle

    As far as slender column design is concerned (assuming braced column), the moment amplification can often be extremely sensitive to the concrete cover. Even increasing the cover from 30mm to 60mm to account for the joggle in the reinforcement at the slab level can have a significant impact. Can...
  7. Drapes

    Section 6.2.3 Robustness - Minimum Lateral Resistance of Connections &amp; Ties

    Will locate the tie reinforcement over the width of the column and extend it far enough into the slab to mobilise enough diaphragm reinforcement. To determine the amount of diaphragm reinforcement engaged, thinking of a strut and tie model where say a 45 degree strut angle fans out in two...
  8. Drapes

    Section 6.2.3 Robustness - Minimum Lateral Resistance of Connections &amp; Ties

    Thanks for providing such a comprehensive summary Agent666, just what I was looking for. Taking 5% of total axial compressive load seems intuitive to me. A few follow up queries: 1. Would it be reasonable to extend the tie reinforcement a lap length inboard from the slab edge, in order for...
  9. Drapes

    AS3600 - Cl 10.7.4.5 Column Joint Reinforcement

    Thanks for all the feedback everyone
  10. Drapes

    AS3600 - Cl 10.7.4.5 Column Joint Reinforcement

    Is this clause only applicable to edge/corner columns that are part of a moment resisting frame building, or edge/corner columns in general? The SRIA Guide to Seismic Design & Detailing of Reinforced Concrete Buildings in Australia appears to suggest that it is only applicable to OMRF and IMRF...
  11. Drapes

    Section 6.2.3 Robustness - Minimum Lateral Resistance of Connections &amp; Ties

    Any further comments on my previous post folks? Also, when designing the column top and bottom connection for this minimum load, can we rely on the existing longitudinal column reinforcement that extends and is fully developed through the slab joint to resist this load (via shear friction...
  12. Drapes

    Crack-Bridging Ability of Waterproofing Membranes - Hydrostatic Slabs

    Hi everyone, Just touching base on this again to hopefully close out - any further comments or insights on my latest queries would be much appreciated. Thank you all
  13. Drapes

    Section 6.2.3 Robustness - Minimum Lateral Resistance of Connections &amp; Ties

    Thanks blihpandgeorge, thats great. Do others also agree that it can be based on the load being transferred from the floor? Is there any general guidance outside of the code which I can refer to that explains the logic for this?
  14. Drapes

    Section 6.2.3 Robustness - Minimum Lateral Resistance of Connections &amp; Ties

    With reference to section 6.2.3 and 6.2.5 under Structural Robustness in AS1170.0, does the 5% of the value of G and G+ycQ refer to the total vertical load from all slabs above the connection in question, or just the vertical load from a single slab?
  15. Drapes

    Crack-Bridging Ability of Waterproofing Membranes - Hydrostatic Slabs

    Thanks Ron, sounds like a plan! Do you know what order of magnitude crack widths these sheet membranes can typically tolerate? Is it even necessary to check compatibility of sheet applied waterproofing membranes with crack widths? Or are they generally robust enough by default? From the...
  16. Drapes

    Crack-Bridging Ability of Waterproofing Membranes - Hydrostatic Slabs

    Thanks everyone for your feedback and insights. To give a little more context - this is not a remedial measure, and not considering a liquid applied membrane or filler. We have a hydrostatic slab (below the water table level), which will need to be fully tanked. A sheet applied membrane will...
  17. Drapes

    Crack-Bridging Ability of Waterproofing Membranes - Hydrostatic Slabs

    How do others approach this? And what crack widths are acceptable for say a hydrostatic slab if a waterproofing membrane is present?
  18. Drapes

    Robustness &amp; Progressive Collapse - Key Element Column Design

    Yes understand the origin of this load - Ronan Point I believe had a significant role to play. Yes, the structure is monolithic and will be adequately tied at the column/slab interface. But how does the facade/partition walls being weaker than the slab have anything to do with justifying...
  19. Drapes

    Robustness &amp; Progressive Collapse - Key Element Column Design

    Thanks HTURKAK. The column is actually being restrained by slab only (no perimeter beams), however seems a bit excessive for the slab to be designed for a 34kN/m2 load applied over a 6m x 6m tributary area. Would be struggling to make this work without incurring significant cost on every...
  20. Drapes

    Robustness &amp; Progressive Collapse - Key Element Column Design

    When designing key elements for an applied load of 34kN/m2 (such as corner columns on a high-rise) as a way to satisfy robustness and avoid disproportionate collapse, what effective column length do you consider? Is it acceptable to check the column capacity based on a single story height, or do...

Part and Inventory Search