hmm, my little drawing didnt look anything like that when i typed it...
Ill try explane it better, the door is horizontal when closed (and locked with the mag) and swings back on its self (upwards) and round so it is 40 degrees to the horizontal, there is a lip that supports it in that...
This is going to sound like a home work problem but I promise it isn’t!
My boss has given me a task (anyone that reads the automation posts will be aware of this) and there is one final part of it I need to show and that is the forces acting on a door I have to design, I know this is simple but...
HAHA, i dont think my boss does like me, but unfortunatly it is not a set up,
thanks for the replies, by volume flow capacity do you mean volumetric flow rate, i have done a little research and come up with this below, I would appreciate an opinion on it, bearing in mind I’m not an engineer...
Cheers, unfortunately I cant hook it up, they are not local, I have contacted them regarding the supplier, but they don't seem to know...
Is there no way of calculating a rough number? what additional information would I require?
Cheers
John
Thanks for the tips, that helped quite a bit,
This had been put on the back burner, but im back on it again now, and i have just been informed the client already has a cylinder they want us to use.
I cant get access to the cylinder and my supervisor wants me to work out how fast the cylinder...
Hi all, Ive been drafted by my boss to size some pneumatic cylinders, i normally work more on the programming side so its going to require me to remember calcs i haven't done since college (30years ago), anyway, ill show you what ive come up with and hopefully you will be able to show me where I...