Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. 123revolution

    MANUAL VALVE OPERATORS

    Many thanks, man.
  2. 123revolution

    MANUAL VALVE OPERATORS

    Hi totallockout, Hmm... this sounds interesting. Can you furnish me with details?
  3. 123revolution

    MANUAL VALVE OPERATORS

    Many thanks for the quick response, gerhardl.
  4. 123revolution

    MANUAL VALVE OPERATORS

    Hi Gents, My company recently purchased a 20" butterfly valve with gear operator when what should've been procured was one that was operated hydraulically. My question: Is it possibly to change the operator from the gear type to a hydraulic operated one? Thanks, d_revolution.
  5. 123revolution

    Antistatic device pertaining to bronze ball valves

    Hi McDermott1711, Thanks for the response. I also did go to the referred literature and got the clarification I needed.
  6. 123revolution

    Antistatic device pertaining to bronze ball valves

    Hello, I would like some help pertaining to why or (and) why not anti-static devices are required on bronze ball valves.
  7. 123revolution

    NACE MR 0175/ ISO 15156 REQUIREMENT

    Thanks guys, I actually did not think ISO 15156 was a requirement for the fresh/sea water service , I just needed confirmation.
  8. 123revolution

    NACE MR 0175/ ISO 15156 REQUIREMENT

    No. This is not mentioned in the design document.
  9. 123revolution

    NACE MR 0175/ ISO 15156 REQUIREMENT

    Hi Guys, I'm currently working on installation of Fresh water generators and associated piping in ship or vessel's engine room and would like to get response or advise if NACE MR 0175/ISO 15156 is required in preparing the piping and valves materials take-off for the system. From my...
  10. 123revolution

    PN160 SLIP-ON FLANGES

    Hi Guys, A little help here if you will; I'm looking for slip-on flanges for PN160 and more rating. DO these exist? I see mostly up to PN100 rating and not more. Thanks, hope to hear your advice.
  11. 123revolution

    Gr. 8.8 BOLTS AND NUTS

    Hi Guys, I am working/preparing a piping MTO for a ship's boiler steam lines to be replaced and I'm being advised to use gr8.8 bolts for the (DIN) flanges rated 300# or PN25. Is there any advantage in using this other than using the normal grade b7?
  12. 123revolution

    GRAYLOC ENLARGING AND REDUCING HUB CONNECTORS-DIMENSIONAL DATA

    LittleInch Sorry for the not-so-immediate reply to your 'reply' but I've been quite tied-up with work. Yes, I guess I didn't leave enough information to receive 'enough' help; I am dealing with a 6-inch riser and terminating in a grayloc hub diameter of 8" so I do have a case of using a...
  13. 123revolution

    GRAYLOC ENLARGING AND REDUCING HUB CONNECTORS-DIMENSIONAL DATA

    Well, thanks LittleInch but I did try and it's taking awhile...probably would have to wait more...!
  14. 123revolution

    GRAYLOC ENLARGING AND REDUCING HUB CONNECTORS-DIMENSIONAL DATA

    Hi everyone, I'm a Piping and Layout Engineer currently working on design of an offshore Riser with the intent on using Grayloc hub connectors. I have gone through the Grayloc products online and given all information concerning the standard hub connectors but couldn't find any information...
Back
Top