  1. tab101

    Miami Beach, Champlain Towers South apartment building collapse, Part 02

    @structuralex yes agreed. There are suggestions here that the damage was caused during the building collapse, not prior. And that (for example) the woman who spoke on the phone to her husband and told him about the pool area collapsing before being (presumably) killed in the building collapse...
  2. tab101

    Miami Beach, Champlain Towers South apartment building collapse, Part 02

    I suggest posters suggesting that all damage to the pool deck/parking area is solely a result of the main building collapse should review the collapse footage again https://www.youtube.com/watch?v=KR29pLccutY There are mere seconds between the 2 sections of the building collapses. Obviously...
  3. tab101

    construction tolerances of steel pile caps and structural steel

    Essentially it's a steel plate welded to the top of the steel pile, with gussets between the plate and the pile. Don't disagree with you about the division of work. Unfortunately that's the way it was sorted before I got here so now I have to resolve the issues that arise.
  4. tab101

    construction tolerances of steel pile caps and structural steel

    Hi all, I'm working on a construction project with steel pile caps and I've only ever worked with concrete pile caps so I'm a bit unsure of how to deal with this issue. In terms of vertical tolerance, normally with concrete pile caps, the cap is poured low (eg 50mm below steel base plate)...
  5. tab101

    Epoxy grout poured too low beneath skid

    Just as a bit of background, I work for the construction contractor, which means I don't have access to any detailed design calculations eg loads. In terms of what was said at the meeting etc, I'm not even the contractor engineer looking after/responsible for this scope. I decided to come along...
  6. tab101

    Epoxy grout poured too low beneath skid

    We did ask about the bolts taking the shear and the epoxy being for bearing. I don't remember exactly what the design/owner engineers said, but essentially the epoxy needs to take the shear (the bolts are canister bolts -...
  7. tab101

    Epoxy grout poured too low beneath skid

    Hi all, after some advice here. We have an issue whereby our grouting sub-contractor has poured epoxy grout too low in some sections below a large skid (approx. 15m * 10m, 100tonne). The top of grout is currently between about 10mm and 40mm below underside of skid (it has been poured correctly...