Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. wafer71

    shalow flow measurement in a DN200 pipe

    I have used a propeller flow meter with good success in similar applications. Gravity feed 24" water line with varying liquid height in the pipe. Large bore pipe to allow water to flow freely.
  2. wafer71

    Direction of flow through valves

    Before one can answer this question, you must look at the trim and sealing surfaces. On some ball valves, the seats are designed to have the process apply pressure on the ball when closed which in turn applies pressure on the seal to aid in sealing the valve closed. Best is to always look at...
  3. wafer71

    Instrument Junction Box segregation (ESD/PCS)

    Good morning "aranoche". Clients state the requirements for segregation for reasons such as ease of maintenance and overall awareness with respect to what I/O in a given JB is used for. Thus clients will do everything from use red or yellow lamicoids on the front of a JB with SIS on it as...