Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. bo7winner

    water quality for pipeline hydrotest

    Hi all, water analysis result shows sulfate content 900 ppm which is inconsistent with company specification,I am asked to submit the deviation to release pipeline for hydo- test:. a)is any standard for hydro test water quality acceptance criteria? b) shall I add biocide & which type to avoid...
  2. bo7winner

    ASSET INTEGRITY

    thank you all for your reply. I am not waiting for response just for more question as have no problem with question above. Bo7winner
  3. bo7winner

    ASSET INTEGRITY

    Hi all, I am touching for asset integrity lead position for oil& gas central process facility project. I need your guidance expecting any question for this interview. your help is much appreciated. Bo7winner
  4. bo7winner

    Isolating kit instead of isolating joint in ICCP

    have enough kits with spare parts.many thanks to you for your support.
  5. bo7winner

    Isolating kit instead of isolating joint in ICCP

    actually this line will be used only for max one year as line for start up that's why we intend to use isolating kit instead of IJ. Thanks
  6. bo7winner

    Isolating kit instead of isolating joint in ICCP

    Hi LittleInch, thx for your response. fluid: gas; Design Pressure (barg):92 Receiving Pressure (barg) :55-65 Design Temperature (˚C) :-10 / 85 Operating Temperature (˚C):20-50
  7. bo7winner

    Isolating kit instead of isolating joint in ICCP

    Hi all, For a buried pipeline with impressed current CP system, I am wondering if it's possible to use Isolating kit on above ground flange instead of monoblock isolating joint. thanks in advance for your support. bo7winner
  8. bo7winner

    fiber optic

    thanks for reply. 1550 nm and 1330 nm for wavelength.
  9. bo7winner

    fiber optic

    thx zappedagain for your reply. I confirm,our tester is properly calibrated. warm regards
  10. bo7winner

    welding X52 to X65

    Thx DekDee for your clear answer. dear all,sorry for my delay to replay I was in desert area missing net coverage. @XL83NL, I am interested to any answer can help but as I said I was offline. warm regards
  11. bo7winner

    welding X52 to X65

    LittleInch, shall I submit new WPS/PQR or which WPS ? bo7winner
  12. bo7winner

    welding X52 to X65

    Hi all, I am working on pipeline project,please let me know the possibility to weld 4" X52 to X65 knowing that I have separate WPS under API 1104 for each one. Thx bo7winner
  13. bo7winner

    chain link fence material

    Hi all, anyone help to make difference between diamond and galvanized chain link mesh. thx bo7winner
  14. bo7winner

    fiber optic

    Hi all, the OTDR testing of 14km fiber optic shows attenuation -0.174 dB,it my first time seeing negative attenuation,please help to interpret this value knowing that the acceptance criteria is 0.1 dB as per specification. THx
  15. bo7winner

    Hi all, the OTDR testing of 14km f

    Hi all, the OTDR testing of 14km fiber optic shows attenuation -0.174 dB,it my first time seeing negative attenuation,please help to interpret this value knowing that the acceptance criteria is 0.1 dB as per specification. THx
  16. bo7winner

    Hi all, I am working on piping wor

    Hi DGrayPPD, design code BS 1873,reason for change is the long time of delivery of required material A216. Regards
  17. bo7winner

    Hi all, I am working on piping wor

    Hi DGrayPPD, thanks for reply,below my response to your qustion: commodity: piping NPS:6" design temp:-20 / 85 c design pressure:92 bar I don't have the ASTM standards. bo7winner
  18. bo7winner

    Hi all, I am working on piping wor

    Hi all, I am working on piping works in gas project. our contractor suggest to use body material ASTM A216 WCB for globe valves instead of required ASTM A694 F65. Does any one help to know the standard/norm requirement,shall accecpt or reject this suggestion? please help me . bo7winner
  19. bo7winner

    Hi all. please let me know if is

    Hi all. please let me know if is acceptable to pose pipe welded joint on support. bo7winner
Back
Top