Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. 69Firebird

    ASME IX & API 1104 Time between passes

    In API 1104 the only time between pass that is an essential variable is between the root and the hot pass. See para 5.4.2.8. It can be allowed to cool down and left after the hot pass. Just need to make sure it is properly supported to prevent cracking, follow the WPS preheat, and properly clean...
  2. 69Firebird

    Porosity versus gas pocket API 1104 20th edition

    9.3.9.2 refers to the porosity as depicted in Fig 19 and 20 shows the terms can be used interchangeably- not sure that's even a word- either way they are splitting hairs and should have larger concerns. JMO
  3. 69Firebird

    API 1104 (20th Ed.) Branch Test Destructive Testing Specimens

    From memory, its 4 nick breaks for the branch 90 deg apart. Butt weld jumps up after 12" so if they test on 14" pipe there is twice the number required than if they test on 12"
  4. 69Firebird

    welders qualifications

    Weldstan is correct. We encourage our facilty fabricators to utilize ASME sect 9 procedures for our facilties that fall under B31.4. We have to review fewer procedures and the welders have to take fewer qualification test because of the way the 1104 groupings are.
  5. 69Firebird

    Deck Collapse in North Carolina

    There is another consideration to look at that can contribute to the fastener corrosion. After manufacturers switched to ACQ instead of CCA for lumber treatment most lumber was treated with ACQD as it was probably cheaper. What most people including reputable contractors weren't made aware of...
  6. 69Firebird

    Crack corrosion in stainless steel

    Xray is not a good choice to detect cracks. It will find only a small percentage of them. It is too dependant on orientation.
  7. 69Firebird

    api 510 recertify exAM

    The API website will have the pertinent references listed i believe I found them listed on the recert page but its been over a year since I looked at it. the exam should be 25 questions and will cover any updates in the code during the last 6 yrs. Its open book and no study guide.
  8. 69Firebird

    Flush Type Clean out Door NDT Reqd.

    The manual UT tech should be able to determine if he has the room to get the sound thru the weld. They very well may get a signal at the gap where the RF plate is gapped, however simple trig will tell them if thats where the signal is coming from. If i am looking at the detail correctly (4)and...
  9. 69Firebird

    Hydrogen Embrittlement Measured Hydrogen Amount

    I hope this works as due to corp limitations i cant access you tube to copy annd paste a link. Try youtu.be/Wjz8eheh3uxku its a short 9 min video made by DNV and Spectra Energy about hydrogen diffusion. I had never seen this demo before and it was an eye opener. It gets real interesting from...
  10. 69Firebird

    Requirments for writing WPS and PQR's

    I will add in a quick thought here. As you did not state what type of work this is for. If this work is for a pump station or a compressor station I would go with ASME procedures. These facilities are governed by B31.4 and 31.8 and both allow procedures to be written to 1104 or Section IX...
  11. 69Firebird

    Believe I'm underpaid - do I have to seal drawings?

    If I happen to learn of a colleagues pay I do 3 things. I do the job I was hired for at the rate I agreed to do it for no one forced you to accept that wage. I keep that information in my back pocket for an appropriate time- I always felt review/ salary adjustment came once a year unless...
  12. 69Firebird

    API Inspections

    For some they may not have enough work to justify a full-time peerson( in there eyes), and for others they may want the protection of having an unbiased 3rd party, and some insurance companies may require it to be 3rd party as well. There are multiple reasons and its usually different for every...
  13. 69Firebird

    Weld inspection.

    It gets even more touchy if there are labor unions involved.
  14. 69Firebird

    Testing Tension Bolts

    3 from each lot and they must all break above the minimum. The skid more is the only way I am aware of testing, altho there may be other means
  15. 69Firebird

    RADIOGRAPHY THICKNESS LIMIT

    IR-192 is good up to about 3" and cobalt 60 can penetrate 7-8". Obviously as you near the upper limits resolution can be challenging along with the increasing need for back scatter protection as the exposure times increase. We have used Cobalt 60 on many section 8 vessels in the 4-5" material...
  16. 69Firebird

    API piping inspection certificate

    1169 is a new certificate and pertains to building of new cross country pipelines. 570 is inspection of in-service piping generally a terminal or refinery. I believe they have to be taken at an API test site. I do not believe they can be taken on-line but I may be mistaken. check out api.org it...