  1. HEX07

    Strength reduction of existing tubesheet by drilling few additional holes

    Additionally I would also like to ask, drilling of tubesheet at installed position (Installed vertically) can be possible or not??
  2. HEX07

    Strength reduction of existing tubesheet by drilling few additional holes

    @ SnTMan (Mechanical), basically these bolts are required to hold the perforated plate below the tubesheet. My concern is whether remaining tubesheet thickness will be sufficient enough to withstand the design criteria after drilling 38 mm deep holes or not?? Additionally, where we consider tie...
  3. HEX07

    Strength reduction of existing tubesheet by drilling few additional holes

    Hi...we have a case where we need to fix one perforated plate of 8 mm thickness below the tubesheet exactly alligned with the tube holes (Tubes no = 1000). Tubes dia is 19.05 mm and hole dia on perforated plate is 7 mm. Perforated plate will be fixed with the tubesheet by providing 10 nos of...
  4. HEX07

    Providing online passivation layer inside the column

    We have a case where passivation layer is missing on the upper part of the column and there is slight reduction in material thickness. Column in under operation since long. Now we want to put the passivation layer inside the column. What are the options available. Is there any way to provide the...