  1. volunteera

    AISC Design Guide 4 and 13. Possible contradiction?

    Thanks. Will go through it. It's really pity that DG 16 does not include column checks
  2. volunteera

    Roark's Formula Question

    robyengIT, thanks for the reference and the help again. Very appreciated prex, beta is the value from the table however, it is only limited to a certain values of a a, a1, b. b1 where my values differ from what is given in the table
  3. volunteera

    Roark's Formula Question

    Thanks for the attachment. Can you please let me know what book this is coming from?
  4. volunteera

    Roark's Formula Question

    How can I figure out betta value which is not tabulated in Roark's formula table 11-4 case 1-c? In my case a=1.4b, a1/b=0.11, b1/b=0, Reference is attached http://files.engineering.com/getfile.aspx?folder=a1cdd72d-229b-4fa0-9d83-952a72696f77&file=Roarks.jpg
  5. volunteera

    AISC 2005 Chapter K Limits of Applicability

    AISC 2005 Chapter K is applicable to HSS only with Fy ≤ 52 ksi and Fy/Fu ≤ 0.8...In my case, I am welding a pad-eye to a round HSS which is a drill pipe with Fy=148 ksi & Fu=160 ksi which means both of the requirements are being violated. On the other hand, the pad-eye is only taking 0.5Te...
  6. volunteera

    Relative stiffness of beam and column

    A continuous steel beam is running over four steel columns. The columns are fully welded to the bottom flange of the beam. I have analysed the beam already and it is ok and now want to check the columns. Obviously, because of relative stiffness of the beam and the column, the column will take...
  7. volunteera

    Eccentric truss connection

    Motorcity, That's why for conservativity I pinned the diagonal webs. This will pass all moment on vertical web to stabalize. I think this is the worst case scenario. Thanks for commenting on.
  8. volunteera

    Eccentric truss connection

    I am analysing an open top offshore container with Staad pro. It is a 20ft container made out of HSS truss walls with eccentric KT-connections. As one can notice from below pictures, diagonal web members of side and end walls (which are released from translating moment in all directions) are...
  9. volunteera

    Runway beam BS 2853:1957

    Gents, Thanks for the responses. I've been particularly asked to work with BS 2853:1957 because the original design was done in reference with this standard. neukcm, I'll check BS2853 to see if I can refer to BS2573-1 which I am not very hopeful with. Thanks anyway.
  10. volunteera

    Runway beam BS 2853:1957

    I am checking an existing runway beam to BS 2853:1957. However I can not find horizontal load requirement in the standard. Where I live we apply 10% of the load horizontally to the beam. Is not there any horizontal loading requirements in BS 2853:1957? In BS EN 1991‐3-2006 there is a 5%...
  11. volunteera

    Shell Offset option

    It is a complex model. I am afraid computational time would take ever. HOWEVER, thanks for commenting.
  12. volunteera

    Modelling box section in Ansys with midsurfaces

    I have a tee joint of Box sections (square hollow section) in Ansys WB. Both of them have same outer sizes however thiknesses are different. When i model them with midsurfaces the walls are not matching on which created stress singularities. I was thinking about to model the shells in outer...
  13. volunteera

    Shell Offset option

    I have a tee joint of Box sections (square hollow section) in Ansys WB. Both of them have same outer sizes however thiknesses are different. When i model them with midsurfaces the walls are not matching on which created stress singularities. I was thinking about to model the shells in outer...
  14. volunteera

    AICS 9th Cover Plate

    TehMightyEngineer, Thanks for repling back. Table B5.1, row7. applied to .....between lines of fasteners or welds. In my case, the cover plate projecting out from the egde of flange where the two paralel stream of welds are. I think i have to stick with row 4. What do you think? Concerning...
  15. volunteera

    AICS 9th Cover Plate

    Cover plate is welded to the top flange of an I-Beam in full length. The beam is simply supported and top flange is in compression. AISC 9th Manual Table B5.1 row 4th - Outstanding legs of pairs of angle in continues contact; angles or plates projecting from rolled beams or columns; stiffeners...
  16. volunteera

    Load factor in two opposite slings lift

    Thanks to all for repling back. I appreciate it. The lifting plan was proposed by lifting authority. My role is to check capacity of the upperdeck beams. By the way, I have already rejected the proposal as the flange local and lateral bending failed for a code check. I am exactly in the same...
  17. volunteera

    Load factor in two opposite slings lift

    Concerning with the safety margins i have got weight contingency factor in all cases. In addition, in the very beginning a consequence factor is introduced. This will cover any friction related issues as well. The reason is a hard pipe spool is attached to the valve with a flange connection on...
  18. volunteera

    Load factor in two opposite slings lift

    Now we have got sketches as well. They will start with lifting the valve 1m up to clear the spools (pic 1). Once lifted (Pic 2) chain block C is connected to master link 2 (Pic 3), the valve is cross hauled between B & C (Pic 4), once the cross hauled is complete block B is released for...
  19. volunteera

    Load factor in two opposite slings lift

    Sorry for not making it enough clear. I am checking upper deck beams. Beam clamps will be used to transfer the weight transverse to the beams. I have no issues with lifting appliances.
  20. volunteera

    Load factor in two opposite slings lift

    It is a valve and i am working to AISC standards. The valve will be cross hauled through the numbers of beams located on upper deck. Lifting authority confirms that the load will always be at least on two beams and their lifting plan says the same. My assumption is 0.67 of the load for vertical...