Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations GregLocock on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. robert122

    550V AC Motor protection

    In your case Earth fault relay operates only when the insulation of motor is broke down. It is adviceable to use IP rated motors for operating in wet environments. Earth fault protection is not going to help you.
  2. robert122

    in DC machines, how do commutators convert induced AC voltage into DC ?

    To understand this you have to know the working of DC machines. Actually the generated voltage is always AC. In simple the commutators just conduct in only one way making the current output is always one way.
  3. robert122

    HOW TO DO 350KW GENERATOR MEGGER TEST??

    As far as i my knowledge, megger is used to measure insulation resistance not winding resistance. Megger is used to measusure insulation resistance of generator. Connect one point to generator output terminal and other to external metal part of generator and then start megger.
  4. robert122

    Motor overload setting

    Primary issue is that whether it is adviceable to use three phase motor starter to single phase motor. I dont think it is right. You should not use 3 phase motor starter to single phase motor. Now coming to rating setting, if the setting is less than 125% no damage will be done to motor but it...
  5. robert122

    Generator fault

    In large generators, to protect these types of faults differential protection is used. This differential relay when there is fault in between the intended points, will sense and switches off the generator. This is very common type of protection in generators.
  6. robert122

    Four conductor cable to power and control many devices

    The usage of four conductor cable is not limited to irrigation. In any three phase with neutral circuits, four conductor cables are used. In many industrial and even in some of domestic applications four core cables are extensively used. In all the industrial applications involving three phase...
  7. robert122

    3 Phase Noise

    The type of starter for a motor depends on the starting current of the motor. for small motors, DOL starter is sufficient as the starting current is not very high. but when rating increases, starting current increases and hence has to use different type starters like star-delta starters...
  8. robert122

    Gland Seal Water

    An organ seal is embodied a chamber which houses stationary fixing parts, for example, Lantern Rings, Neck Rings and Gland Packing. The chamber takes into consideration flushing water to be nourish into the fixing range through a food opening. Going through the focal point of the chamber is a...
  9. robert122

    SR Valve Diffusor?

    I would like to say that diffusors is swril diffusers DVR,Round ceiling diffusers DS,Square ceiling HB40,Slot diffusers SDML, having the safety the rules of the value of diffusors,and the process of manufacturing of it. Diffusor is a piece of valve and on a drawing it is stamped as Non Pressure...