Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. GOSP75

    Regarding Radiographic requirement for API 650 storage tank vertical joints

    Dear Members, As per API 650 section -8 subsection 8.1.2.2. Regarding radiography of shell plate vertical weld joints API 650 stated as below. 8.1.2.2 The following requirements apply to vertical joints. one spot radiograph shall be taken in the first 3 m (10 ft) of completed vertical joint of...
  2. GOSP75

    Regarding RT requirement for shell to curb angle joint in API 650 storage tanks

    Dear JStephen, Thank you for clarify my Query. Regards, Shanmuga
  3. GOSP75

    Regarding RT requirement for shell to curb angle joint in API 650 storage tanks

    Dear respected members, In our project we have shell to curb angle with butt weld configuration as below. https://res.cloudinary.com/engineering-com/raw/upload/v1727321119/tips/SHELL_TO_CURB_ANGLE_WELDING_a4s7d7.docx Radiographic requirements applicable for shell to curb angle butt joints...
Back
Top