  1. vignesh47

    check valve in drinage, & Man hole

    I have attached a sketch. Kindly take a look at it http://files.engineering.com/getfile.aspx?folder=f731ca01-da8b-453c-9f3a-6ed382b8fdbb&file=MANHOLE_Model.plt
  2. vignesh47

    check valve in drinage, & Man hole

    Is it advisable to provide a check valve in the soil drainage line(PVC) 2. I have a manhole which has soil, drainage and a pressurized line from RO reject and Backwash. The size of the manhole is 1000mm X 1000mm. The flow from pressurized line is 7.5 l/sec The difference between the bottom of...
  3. vignesh47

    Fittings for drainage.

    In PVC there are two kinds of fittings, one is elastomeric fittings(With a rubber ring in t pic) the other is ordinary with solvent seal. I'm not sure which is better.http://files.engineering.com/getfile.aspx?folder=a9e51347-3fa6-4590-a44a-c718a54d1edd&file=053a24eb-3f5c-46d7-b778-8f16bbc0847a.jpg
  4. vignesh47

    Fittings for drainage.

    This is a drainage system for a hospital. I'm not sure which one is better
  5. vignesh47

    Fittings for drainage.

    Which kind of fittings are preferred for drainage pipes. I have two choices, one is fittings with mechanical seal and the other is fittings with solvent seal. i'm not sure which one to choose. can any one help me out.
  6. vignesh47

    Cutout/Boxout for the WC and Clean out in the raft foundation

    Thank you so much. i convinced our structural engineer to provide the box outs
  7. vignesh47

    Cutout/Boxout for the WC and Clean out in the raft foundation

    What is the use of providing Cutout/Boxout for the floor drain and WC in the raft foundation? is it mandatory?http://files.engineering.com/getfile.aspx?folder=ef84681a-4a1d-4a37-a856-27eca9ab7186&file=12b4885e-063c-4a6c-ace9-ccc1f2fdde63.jpg
  8. vignesh47

    Hydro test of fire fighting lines.

    thank you so much. Now i'm clear that the test can be carried out at 200psi.Its because of the contractor who kept arguing with me that the sprinklers are rated at 12 bar and cant be tested at 13.8 bar pressure.
  9. vignesh47

    Hydro test of fire fighting lines.

    According to NFPA14, the sprinkler system should be pressure tested at 13.8 bars for 2hours. But the sprinklers used in most fire fighting systems are rated at 12bar. will the sprinklers be affected if the system is tested at 13.8bars? whats is the right way to do the pressure tests.