Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. gsakamoto

    PSV Closed Discharge

    Yes, always check any credible case and review the results. It's good engineering practice to check this.
  2. gsakamoto

    Coupling welded directly on an elbow

    Thanks KernOily, you are correct. I assumed that this was a small olet (1/2" - 1-1/2") and the main run elbow diameter was NPS4 or greater.
  3. gsakamoto

    Flexible hoses for LNG transfer

    Thanks, I have reviewed the Trelleborg product lineup. I want to know if there was any Canadian examples that would have compliance (or recorded non-compliance) to CSA Z276 and if any regulators were aware of these products. I haven't investigated any competitors as of yet, but I was made aware...
  4. gsakamoto

    Pipe shoes for SS lines

    Typically you don't want to weld disimilar metals. Just because you can doesn't mean you should. CS clamp supports are cheaper than SS clamp supports.
  5. gsakamoto

    Multiple Y-fitting to split the flow

    All those flanges are going to disrupt the flow. Not to mention that you might not be able to use conventional tools to install those nuts.
  6. gsakamoto

    welded vs flanged

    This question is posed in a way that incurs infinite arguments because we don't have a clear interpretation of what the author is asking for. Ahmad, please elaborate on your criteria.
  7. gsakamoto

    Flexible hoses for LNG transfer

    Was wondering if anyone had experience with using flexible hoses for LNG transfer, offshore tidal application.

Part and Inventory Search