Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Recent Grad Josh

    Wind load on solar panels by edge of roof per ASCE 7-16 29.4.3

    Hi all, I am wondering if I am understanding this section of the code correctly. It seems as though the exposure factor (gamma_E) can only equal 1.5 if the solar panels are located at least 0.5*h away from the edge of the roof (and also meet other criteria). Does that mean solar panels that are...
  2. Recent Grad Josh

    How does CRSI avoid shrinkage and temperature reinforcement requirement in square footings?

    Hello, I was looking at the "Concentrically Loaded Square Spread Footings" Table in the CRSI Design Handbook (2008, pg 13-6), and the required steel which they tabulate falls short of ACI's 0.0018bh minimum. Their values come out to be around 0.00125bh and up. Is there an exception in ACI that...
  3. Recent Grad Josh

    ACI 350 Shrinkage and Temperature Reinforcement Movement Joints

    Hello, I am designing the horizontal reinforcement in a 18'x10' rectangular tank. There are no movement joints, and I'm wondering if I need to satisfy the full 0.005 reinforcement ratio which is required between movement joints spaced at 40' or greater (Grade 60 rebar). Or do the tank corners...
  4. Recent Grad Josh

    Axial force in joists and joist girders from wind load

    Hello, I'm working on a 420'x120' warehouse building made of precast concrete walls. There is one row of columns in the middle of the building, and the metal roof deck is supported by joists at 5' ctrs. The joists span 60' between the wall and the joist girders (which span between the columns)...
  5. Recent Grad Josh

    Live Load Reduction For Different Uniform Loads

    Hi all, If a member's tributary area includes a 40 psf region (living space) and a 100 psf region (public walkway), am I allowed to reduce both of those live loads individually according to IBC 2015 1607.10.1 OR ASCE7-10 4.7? Thanks in advance
  6. Recent Grad Josh

    Slab on Grade Design Help

    dnlv, thanks so much! That's helpful.
  7. Recent Grad Josh

    Slab on Grade Design Help

    Hi all, I'm using ACI 360R-10 to design a slab on grade, but I'm not sure how to account for the load from an interior wall. The load from the wall is something like 3 klf, but assuming the subgrade modulus is k=100 pci, the slab thickness is off the charts. Should I not be using ACI 360R-10...