Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Nasim12345

    Set presure tolerance for PSVs- ASME Section 8, UG-134 D

    Dears While testing the PSVs, we are following the set pressure tolerance based on below ((ASME Section 8, UG-134 D (1)) The set pressure tolerance for pressure relief valves shall not exceed ±2 psi (15 kPa) for pressures up to and including 70 psi (500 kPa) and ±3% for pressures above 70 psi...
  2. Nasim12345

    Investigation requirements in API

    Can you please share me the API paragraph number for such requirements.
  3. Nasim12345

    Investigation requirements in API

    Do we need to investigate the root cause of as received pop test failure if the PSV premature opening. Investigation report need to be shared with operation, Process engineering & TSD etc... During the internal audit, auditors may ask, whether we have conducted any investigation for such failures.
  4. Nasim12345

    Investigation requirements in API

    Dear Sir, when we conduct shop inspection, If any PSVs failed in the initial inspection (if it opens before the set pressure or failed in the leak test) , do we need to conduct investigation. Is it mentioned anywhere in API standards? If the PSV is stuck or not opening 150% above set pressure...
  5. Nasim12345

    Oxygen Service PZV

    Thanks for your reply
  6. Nasim12345

    Oxygen Service PZV

    Dears Is it mentioned anywhere in the International Standards (ASME/API) that, don't use Grease or Molykote on PSV Internals and threads. If yes, can you pls share the same I have read on safety bulletins that special lubricants, which are exclusively made of Oxygen service can be used...
  7. Nasim12345

    Testing a Vacuum Breather Valve

    Tank Breather valve set pressure tolerance is +-10%. As mentioned above, if the valve opens at -9.3, it is acceptable.
  8. Nasim12345

    Bellows design PSVs selection

    If the back pressure is more than 10% of set pressure, bellows design psv need to be used(instead of conventional design), such statement is available in any API or ASME standard? Can i have the paragraph reference.
  9. Nasim12345

    Temperature Correction factor for ASME Section 1 Safety valve from Fukui Manufacturer.

    Dears We have one ASME Section 1 Safety valve from Fukui Manufacturer, set pressure is 45 kg/cm2g. We are testing this PSV in Air test stand. Do we need to apply temperature correction factor for this valve to get the CDTP. Operating temperature is 370 °C. Valve Model: SL431-C2-M2(T) SL...
  10. Nasim12345

    PSV spring material - Tungsten

    Thanks MJCronin. Yes, you are right.. I am referring 1997 PSV data sheet. Finally i came to know that there is a typo error in the PSV data sheet. Based on the spring part number, we confirmed that spring material was "Alloy Steel". However in the data sheet, it was mentioned that it was...
  11. Nasim12345

    PSV test Media

    Thanks for your feedback..
  12. Nasim12345

    PSV test Media

    thanks for your feedback. i will explain you our concern.. Now Process Engineer is filling the PSV Authorization form and test media need to be filled in the form. Based on the test media mentioned on this form, work shop personnel will decide, psv need to be tested in which test...
  13. Nasim12345

    PSV test Media

    Dears, While selecting the psv test media, we need to consider the normal operating condition or relieving condition scenario. My understanding is we need to consider relieving condition. can we have your advice please. Is it mentioned in any international standard Thanks Nasim
  14. Nasim12345

    PSV spring material - Tungsten

    Dears Can you please inform me, what are criteria to select the PSV spring material as “Tungsten “ Thanks Nasim
  15. Nasim12345

    Isolation valves for Furnace/Boiler Safety valves - Section 1

    Dears Anyone can share me, in which paragraph states that, do not install Isolation valve on Section 1 Safety valves inlet, which is installed on Boiler / Furnace. Thanks Nasim
  16. Nasim12345

    Common reasons for Bellows failure - Rev 1

    thread1203-479776 Refer to above thread1203-479776, Common reasons for Bellows failure , don1980 (Chemical) mentioned that " When the PSV goes though a single opening/closing cycle, the bellows may experience hundreds of compression cycles. So the key to preventing bellows failure is to prevent...
  17. Nasim12345

    PSV testing as received condition

    Thanks Obturator for your valuable advise..
  18. Nasim12345

    PSV testing as received condition

    Thanks for your feedback. It is mentioned in the procedure that we need to conduct the initial test "as received condition". However, practically it is not possible. As soon as we received the PSV in our shop, first job is clean the inlet/outlet area & clean psv external body. After...