Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations SSS148 on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Emad Shaaban

    Heat treatment machine power supply issue

    Thank you every one, I tried to find 380/480v step up transformer ,but it seem to be unavailable on the local markets on my region. Can you please suggest other options please
  2. Emad Shaaban

    Heat treatment machine power supply issue

    What if user the standby 380v generator and then increase its excitation,will that affect winding withstanding?
  3. Emad Shaaban

    Heat treatment machine power supply issue

    Hi every one A heat treatment machine (pro heat 35) works with power supply 470v/575v..please see attachment What options I have to make this machine works on 380v power supply
  4. Emad Shaaban

    2MVA generator

    Hi Thanks every body for your valuable instruction. It was very helpful. I was able successfully to get 15v with 24vdc excitation when the rotor spin for about 150rpm I kept following your instructions and I was happy with you for lending a helping hand
  5. Emad Shaaban

    2MVA generator

    We’ve just completed a bearing replacement for a 4-pole, 50 Hz, 2 MVA synchronous generator. Before full commissioning, we urgently need clarification on the following points: Minimum Speed for Voltage Generation: What is the minimum rotor speed at which we can expect the generator to...
  6. Emad Shaaban

    Generator with low IR

    Would you please do that for me please
  7. Emad Shaaban

    Generator with low IR

    We are currently assessing the condition of a three-phase 2.5 kVA, 400V emergency generator, which is used for black start only. During our routine checks, we observed the following insulation resistance values: • Initial readings (before cleaning): • Phase to ground (IR): as low...
  8. Emad Shaaban

    ALSTOM MX3VIR016A PROTECTION RELAY PROGRAME

    Dear experts, I’m working in Generator protection panel that equipped with several ALSTOM relay: MX3AMD20A MX3DPG3A MX3IPG1A MX3IPG2A We need to connect these relays with PC to uploads and downloads the configuration files rather than doing it manually. Iam trying to find what is the PC...
  9. Emad Shaaban

    Electrical motor with rotor issue

    Thanks for every body, Ed, Can you make it more clear, If we loaded the motor at 110% and its speed get more slower ,does that mean the its rotor ,stater or mechnical ? same fore nosie ?
  10. Emad Shaaban

    Electrical motor with rotor issue

    Hi everybody A 1800kw electrical motor running with normal temperature and current but with a humming noise.CBM team saying that no vibration has detected because of bearings or a mechanical issue, however the vibration specturm analysis shows frequency of 100hz beside the Ffund 50hz .We are...
  11. Emad Shaaban

    Nuisance tripping in Sepam T40

    Thanks for all of you I have already found an evedance of the phantom voltage that lasts less than 30ms as seen in the I24.. Now to connect a load resistor ,how can I determine the proper size f this resistor .
  12. Emad Shaaban

    Nuisance tripping in Sepam T40

    Hi I thank you for your response 78T is done using Sepam 2000 d22 Both LV and HV sides use T40 and the external trip coming directly from LV side Sepam (soft contact) Can you explain what u mean by DC ground ? Yes the external trip cables that come from LV side are 2km long and it’s a multi...
  13. Emad Shaaban

    Nuisance tripping in Sepam T40

    The Transformer feeders in our plant are running by Sepam T40s at both primary and secondary sides. During the last 8 years we encountered issues that happened quite several times ,in which the Sepam of Primary record an external trip and open its SWG.. This configured external trip input is...
  14. Emad Shaaban

    Defected 200kw Motor rotor

    thank you Panter. Is there any space to tell me more about these methods
  15. Emad Shaaban

    Defected 200kw Motor rotor

    Is there any method to detect failure in the rotor of a 200 kW motor that produces a humming noise? In a previous experience, a similar motor exhibited a similar noise, and upon disassembly, we found that its rotor had elimination gaps. I am wondering which technique could help determine...
  16. Emad Shaaban

    Transformer humming

    Thank you unclebob the picture i attached is for out put current when charger was connected.battery charger is 40kva used as UPC
  17. Emad Shaaban

    Transformer humming

    50kva transformer supplying battery charger system start making a loud humming sound with load and. With noloaf ,transformer insulation resistance is high,but when using scope meter,output currents was distorting any help Wave form...
  18. Emad Shaaban

    Medium Voltage switchgear panel fault

    I would prefair to pull the cable out of the Dameged panel and make a splice in cable room if possible

Part and Inventory Search