Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. Jagmtr

    Gasket position in flange

    Greeting to everyone I have one flange where gasket is placed near flange id=1000mm with gasket width 13mm. Internal design pressure is 100 kg/cm2 & 150 deg c design temperature. Flange pcd is 1283 mm Later after procurement I come to know that gasket shall be placed always near to pcd for...
  2. Jagmtr

    thread794-439534 Greetings to ev

    Thanks sntman I followed your suggestion. Pitch circle diameter, large hub thk & gasket od could reduce flange thk I choose to increase gasket od & now problem resolved
  3. Jagmtr

    thread794-439534 Greetings to ev

    thread794-439534 Greetings to everyone I have come across in very strange situation I have reverse flange which was designed for grooved metal gasket having m & y value Now I am looking to qualify this flange for diaphragm gasket which is having m=0 & y =0 I was thinking that my flange...
  4. Jagmtr

    hydrotest pressure

    Hello everyone i have some doubts related to hydro test pressure my first doubt is, does selection of ug99b or ug99c depends upon shop or field hydro test. i have understanding that selection does not depend upon whether we r performing shop or field hydro test. we can considered anyone in...
  5. Jagmtr

    ring stiffeners on flat head & axial stiffeners on cone

    Hi guys I am using PVelite software for my design. when i am considering cone to cylinder shell junction as a line of support, my cone thickness is increasing very much. I understand that it is only due to moment of inertia requirement of junction. It is only our choice to choose junction...
  6. Jagmtr

    ring stiffeners on flat head & axial stiffeners on cone

    Thanks guys for your kind response. I can consider circumferential stiffeners for cone which design is possible as per code. Can you suggest me any analytical method for flat head stiffeners design?
  7. Jagmtr

    ring stiffeners on flat head & axial stiffeners on cone

    second figure in continuoushttps://files.engineering.com/getfile.aspx?folder=e1dd7891-acc1-4071-a781-7f7daf8702f8&file=Capture11.PNG
  8. Jagmtr

    ring stiffeners on flat head & axial stiffeners on cone

    Hello everyone. I have cone with flat head closure. I need to place ring stiffener on flat head & axial stiffeners on cone section for external pressure. I am attaching figures for better understanding. I am not getting any clause for such stiffeners in ASME section viii div 1. please suggest...
  9. Jagmtr

    knuckle radius of eliptical head

    @Geoff13, i have understood your point. Thank you all for your kind response. regards,
  10. Jagmtr

    knuckle radius of eliptical head

    @Geoff13 Factor k1 is given in table UG-37 & required to calculate "tr" as mentioned in UG37(a)nomenclature. "tr" is required for reinforcement calculation so As you said, table UG-37 is used for reinforcing calculation. but similarly when we look 1-4(a) nomenclature of "L= inside crown...
  11. Jagmtr

    knuckle radius of eliptical head

    @r6155 I have concern only for changes in ellipsoidal profile by changing ratio D/2h. regards,
  12. Jagmtr

    knuckle radius of eliptical head

    Hello everyone. when we have different D/2h in ellipsoidal heads we have different crown radius by using table UG-37, sec viii div 1. So does we have different knuckle radius for different D/2h in ellipsoidal heads by using table 1-4.4 or table 1-4.4 is only applicable with appendix 1-4f(2)...
  13. Jagmtr

    openings in flat head ASME section VIII div 1

    Thanks david for your kind response.
  14. Jagmtr

    openings in flat head ASME section VIII div 1

    Hello everyone, I have following doubts in understanding UG39 & UG36 ASME section VIII div 1. 1. UG36 is applicable to flat heads or not. I have this doubt because it seems that UG36 is all about formed heads not about flat head. 2. UG39(a)stated that:"The rules in this paragraph apply to...
  15. Jagmtr

    UW-16(f)(2)

    I was thinking same but was not sure. Thanks SnTMan for your kind response
  16. Jagmtr

    UW-16(f)(2)

    Hello all, I have below one question that may be very silly but i am stuck to find the answer. "UW-16(f)(2) stated that:"(2) Fittings not exceeding NPS 3 (DN 80) shown on Figure UW-16.1, sketches (x), (y), (z), (aa), and (bb) may be attached by welds that are exempt from size requirements...
  17. Jagmtr

    Emergency vents for caustic soda solution

    Thanks Geoff13 for your kind response. I think if we think about boiling of stored liquid then we will have to look the boiling point, heat transfer rate, exposed surfcace area, heating time and other points. I am not aware of the boiling point of 40% caustic solution but for pure caustic...
  18. Jagmtr

    Emergency vents for caustic soda solution

    Thanks horacio. Thanks MJcronin. Its small size tank with MOC sa516gr60 with steam heating coil. From your answers i am sure for no need of emergency vents. Overflow & normal vent nozzles are already considered. Regards,
  19. Jagmtr

    Emergency vents for caustic soda solution

    Hi friends, I need a help. I have to design a storage tank to store 40% caustic soda solution. My roof to shell joint is coming non frangible. So i think for emergency vents. But i understand that my stored product is non flammable so emergency vents are not required. There is also heating...
  20. Jagmtr

    shell manhole neck thickness

    Thanks mk3223 for your kind response. Thanks HTURKAK for your kind response. @HTURKAK, actually required reinforcement can also be achieved from higher shell thk & RF pad. So if we have higher shell thickness or higher RF pad dimensions then is there any clause where we can consider lower...
Back