Water analysis report says conductivity is actually <150 μS/cm and dissolved oxygen is <20 μg/kg. There's Hydrazine (200 μg/kg) in the water. pH is 9.5.
But put Class 150 valve in.
Hi.
I'm wondering what's the possibility of galvanic corrosion when welding CS (1.0345 / A285) valve to SS (1.4307 / 304L) pipe with 309L filler metal?
H2O conductivity is 30 mS/m (300 μS/cm), temperature 50° C (122 °F), pressure 3 bar (43.5 psi).
Hi.
These questions are for those, who are familiar with Nusselt number correlations and PHE research history.
Q1:
Rosenblad and Kullendorff (1) had jD=0.273 x Re-0.303 for the correlation in their experiment. But Manglik (2) proposed Nu=0.289 x Re0.697 x Pr(1/3) for the correlation according...