@FEAway
Thank you for the response.
Yes the cf and cr are the goldak parameters.
I am converting a pipe of dimension 114 outer diameter with 6mm thickness and 400 mm length to an axisymmetric model. If its a 3d model we can go with the 2*pi*r/V as the step time .But when it comes to the...
If I am using a DFLUX model for welding with cf=4 and cr=8 for a 2d plate with 400 mm length and 6 mm thickness. Suppose the velocity is 1.33mm/s. What should be the step time I have to use for the heating?
is it cf+cr/v ?
I have 47 license available out of 75. and I have used 32 threads to run the analysis, which requires 21 license only. Once the job is submitted it is not running, but its showing till submitted. Do I need anything else to start it running?
Dear all,
I am using a system with Intel (R) Xeon CPU E5- 2620 v4 @2.10GHz ,128 GB RAM,DUAL CORE , Nvidia Quadro P2000,Windows 10 pro,VS2013,XE2016 and Abaqus 2017.Though I installed CUDA 10.1 and given proper lines in the Abaqus environment file, after enabling the GPGPU acceleration in...
How to enter the temperature dependent mechanical properties such as elasticity, plasticity etc. in Abaqus using UMAT subroutine?
I want to enter the temperature dependent mechanical properties of two different materials using UMAT subroutine. Can anyone suggest the code logic?.
This to call...
Dear all,
When we transfer the temperature from heat transfer analysis to displacement/stress analysis(Sequential) in Abaqus, Can we transfer the elemental temperature, or only nodal temperature is possible? if yes
1.How can we transfer the elemental temperature(TEMP) in sequential analysis...
@FEAWAY
I tried calculating the heating/cooling rate by DTEMP/DTIME using USDFLD, but I am not sure about the working of DTIME.
DTEMP--temperature incremenet
DEAR ALL
The below given is the user subroutine I have used to incorporate the phase transformation phenomenon after welding. The code runs fine without phase transformation effects. But when I incorporate the austenite and martensite values the results are not matching?
1.The residual stress...
Dear all,
I want to calculate the temperature difference in a heat transfer analysis. But I am getting the same values in the filed and state variable, which leads to zero difference in temperature. Can anyone help me to find out "how to calculate the temperature difference between the last and...
Dear all,
I am trying to get the TEMP output using the GETVRM subroutine.But after the analysis when I check the defined state variable the TEMPERATURE VALUES are zero.Can any one help.Attaching the inp and subroutine with...
Dear IceBreakerSours,
Thanks a lot. This is what actually I expected. Sorry for make you confusing.
Its part of research. I have to find new possibilities .Not sure how far it is possible. That's why I am taking experts opinion.
Now I got one from you and its really worth.