Thankyou everyone for your replies
this is a replacement pump .There were 2 sets of KSB pumps with head 50m and 35m3/h flow for one pump. But the actual flow was around 24m3/h. So decided to replace with flow serve pump @50M and 100m3/h .
pump sets are in parallel
measuring flow using Siemens...
good evening friends ,
recently installed a new flow serve pump with flow=100m3/h and head 50m and is delivering only 35m3/h.please explain the possible reasons were we have gone wrong .
Thank you all...
thank you every one for your replies ,
its a ductile iron pipe with cement lining .DN 600
pressure in pipe around 8-12 bar
flow 500-600 m3/h
the pipe was laid 3 meters below the ground
service ; more than 10 years
recently there was a leak .while trenching we found heavy rocks...
Can anybody tell me how this hole formed in this pipe line ?
thank youhttps://files.engineering.com/getfile.aspx?folder=6eb6c957-8886-4227-9201-491acbcd3710&file=WhatsApp_Image_2020-02-02_at_9.25.46_PM.jpeg
hello every one ,
What type of coupling can be used to connect dn 600 schedule 10mm and dn 600 schedule 15 mm di pipe.
please also mention the od range .
thank you
Hello all ,
Can anyone explain what is it meant by this c- in the image attached
Thank you https://files.engineering.com/getfile.aspx?folder=0bcd8bb6-28a6-43ad-a835-e3b690e62a98&file=WhatsApp_Image_2020-01-19_at_12.08.17_PM.jpeg
Hello every one,
Please tell the difference between the flange /dimensions of a NRV of DN80 PN 16 & DN 80 PN25
I need to replace the NRV(Dn 80 Pn 16)of a pump.the delivery pressure of the pump is 16 bar ,so i was planning to replace the NRV with pn 25.so the dimensions ,bolt size of this DN...
Thank you for the reply .we have Two surge vessels connected to the main discharge line of four pumps connected in parallel .The design pressure of the surge vessel is 9 bar whereas the discharge pressure of one pump is also around 9 bar .at a time 3 pumps will be operational.how will i know...
Thank you every one for your replies.
Itsmoked :this was not always the case .the problem arises before 5 to 6 months and our company just got the new maintenance contract
this pump is operated through scada and a mov is also there after discharge and is always kept open
waross: There is a...
A abb squirrel cage 3 phase induction motor 415V ,585A ,1455 rpm coupled to a kirloskar multi stage pump with h=320m,q=216m3/hr power 215kw ,rpm 1487 is tripping while stopping the pump.
While stopping the motor the current reading is going high and motor is going to trip(please check video)...
A abb squirrel cage 3 phase induction motor 415V ,585A ,1455 rpm coupled to a kirloskar multi stage pump with h=320m,q=216m3/hr power 215kw ,rpm 1487 is tripping while starting the pump.does this problem occurs due to water hammering .