Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Sherifhosny

    Double check valve

    When and why we use double check valve arrangement? And what are the main considerations? Specifically in refineries.
  2. Sherifhosny

    Fertilizer (urea) piping design

    What are the main considerations when doing the design (routing) of a high pressure urea line?
  3. Sherifhosny

    piping and equipment insulation

    how can I choose the type and calculate the thickness of insulation for equipment and pipes? is there a tool for this or a book ?
  4. Sherifhosny

    globe valve / piston valve on steam line

    can globe/piston valves be installed on a steam horizontal line with the steam in a horizontal position also?
  5. Sherifhosny

    Vacuum breaker

    the vacuum breaker is there so as to protect against this scenario: there is a temperature control valve at the steam inlet, when it throttles, the pressure will drop, maybe it can reach vacuum pressure, so it start sucking condensate, that is why the vacuum breaker is installed. you can see...
  6. Sherifhosny

    Vacuum breaker

    Hello, I am working on two steam systems, one of them is 10 bar and the other is 37 bar. before the heat exchangers of each, there is a vacuum breaker installed. the thing is I can't find a vacuum breaker for the 37 bar system. so is there some other solutions to use instead of vacuum breaker...
  7. Sherifhosny

    Steam trap selection

    Good morning I was asked to make the selection of two steam traps after a heat exchanger. what I see in the PID ( in the attachment) is that they use two steam traps, one of them is the normal one and the other is for the start-up. is the start-up one needed here, given that it is a condensate...
  8. Sherifhosny

    What should be the connection betwe

    @gerhardl Is this the connection you mean between the valve and the hosehttps://files.engineering.com/getfile.aspx?folder=aea9fdb4-c77a-4c8b-8009-9f1e0dea2175&file=5CZE0_AS01.jpeg
  9. Sherifhosny

    What should be the connection betwe

    @gerhardl Yes, I thought of doing that set in the pit. But that is not the connection used in the old plant.
  10. Sherifhosny

    What should be the connection betwe

    @mk3223 The application is sewage water removal. The size of the line is 25 mm
  11. Sherifhosny

    What should be the connection betwe

    What should be the connection between a pvc ball valve and a flexible hose that will go to a sewage pit. Also is better to just hang the hose loose in the pit or connect it to a pipe.
  12. Sherifhosny

    strainer

    Thanks every one for the great support
  13. Sherifhosny

    strainer

    I was asked to make the technical specification for the strainers we have in the PID in order to send it to the suppliers asking for quotations. What are the information I should put in this technical specification?
  14. Sherifhosny

    Steam trap technical specifications

    @quark Thanks for the answer, what do you mean by -Degree of subcooling -MOC of components
  15. Sherifhosny

    Steam trap technical specifications

    I was asked to make the technical specification for the steam traps we have in the PID in order to send it to the suppliers asking for quotations. What are the information I should put in this technical specification?

Part and Inventory Search