¡Thanks you so much georgeverghese and Heaviside1925 for this nice information!. Reynold's number for this case is as follow:
Raw data: flow velocity3 m/s,
pipe diameter: 2400 mm,
kinematic viscosity: 1 ×10-6 m2/s (aprox)
Result: Reynolds Number Re=7200000
Flow type - turbulent
A material...
Actually, the new real DN2400 and this big size is cause it's the main seawater feeder. Is the first inyection poit of chemical and it's necessary for specific requerement. Traditional static mixer (with internals)would be expensive...
Hi everyone, I working in a injection chemical process for entrance of RO system, and the principal Pipe of feed system have 2600 mm of diameter. We have a proposal for material. We think in teflon for all the body of this injector with 30ª of inclination respect to the vetical.
Any of you have...
Hi everyone, I working in a injection chemical process for entrance of RO system, and the principal Pipe of feed system have 2600 mm of diameter. We have a proposal for material. We think in teflon for all the body of this injector with 30ª of inclination respect to the vetical.
Any of you...